1
13
-
Models FDU224KXE6, 280KXE6
B
P
JD
0
0
1
Z
2
3
0
I
Relay for FM
Thermistor(Remote controller)
Thermistor(Heat exchanger )
Thermistor(Return air)
Model capacity setting
SW6
Thc
Th −R1,2,3
Th −A
X1−3,6
Operation check, Drain motor test run
TB2
Terminal block(Signal line)(□mark)
Tr
SW7−1
Transformer
TB1
Terminal block(Power source)(□mark)
I
I
I
I
FS
CF
FM
Float switch
Capacitor for FM
Fan motor(with thermostat)
I
F
Fuse
Connector
CNA〜Z
1,2
I
1,2
Indoor unit address: tens place
SW1
SM
Stepping motor(for electronic expansion
Indoor unit address: ones place
SW2
Indication lamp(Red−Inspection)
Indication lamp(Green−Normal operation)
LED・3
LED・2
SW3
SW4
Outdoor unit address: tens place
Outdoor unit address: ones place
SW5−1
Automatic adjustment/Fixed previous
SW5−2
Indoor unit address: hundreds place
Live Superlink terminal setting(for spare)
JSL1
version of Superlink protocol
■mark
Closed−end connector
valve)
52FL,FH
Electromagnetic contactor for FM
I
Connector for branching
controller of heat recovery
3−pipe systems
BK
BL
BR
GR
Black
Blue
Brown
Gray
OR
Orange
RD
Red
WH
White
Y
Yellow
Y/GN Yellow/Green
P
Pink
5 or 6 wires
WH
OR
OR
Y
Y
BL
WH
BK
BL
WH
OR
OR
OR
Y
Y
Y
RD
WH
BK
WH
WH
WH
RD
WH
WH
WH
WH
WH
WH
WH
RD
X Y
X Y A
M
Y
B
WH
WH
WH
WH
RD
between indoor units
Power source line
220ー240V〜 50Hz
(Single−phase)
Power source
220V〜 60Hz
Power source
Thc
BK
Y/GN
Y/GN
Y/GN
220ー240V
Tr
line
F
(6.3A)
F
(6.3A)
t°
1〜
M
M
1〜
JSL1
(20S)
(SVH)
(SVG)
(SVE)
t°
t°
t°
t°
Earth
Remote
controller
XR5(Remote operation input:
volt−free contact)
(Operation)
(Heating)
(Thermo ON)
(Inspection)
Option
Superlink(spare)
For Heat recovery
3−pipe systems
Control PCB
Color Marks
Mark
Color
Notes 1. indicates wiring on site.
2. Use twin core cable(0.75〜1.25mm )at signal line between indoor unit
2
and outdoor unit, and signal line between indoor units.
3. Use twin core cable(0.3mm
2
)at remote controller line. See spec sheet
of remote controller in case that the total length is more than 100m.
4. Do not put signal line and remote controller line alongside power source line.
Signal line(Shielded cord)
Signal line
between indoor units
CNK2
L
TB1
CNT
XR1
CNI
RD
2
WH
WH
FM 1
L
H
I
52
BK
RD
1
P
P
RD
CNF2
CNF2
CNF2
52FL
WH
8
52FH
WH
8
7
RD
7
BR
BR
BK
CNFX
Option
WH
RD
BK
WH
BL
CNW2
19V
CNW1
SW2
SW6
SW5
F(3.15A)
+12 1
X6
X1
X2
X3
1
9
7
3
5
C
L
M
UH H
3
1
CNW0
CNF3
CNF5
WH
WH
L
H
CF 2
CNF5
CNF5
CNF3
I
P
CNF3
P
FL
52
FH
52
FL
FH
52
CF 1
I
2
3
4
5
6
XR2
XR3
XR4
1 2 3 4 5
BR
WH
Y
OR
SM
SW4
SW3
SW1
CNA
CNM3
Th −A
CNH
3
CNB
1
RD
1
WH
BK
TB2
BL
RD
RD
3
3
5
6
4
4
RD
LED・2
LED・3
FS
I
FM 2
5
6
N
RD
BK
BK
SW7
I
1
2
Th −R3
I
GR
5
6
Th −R2
I
3
4
Th −R1
I
BK
1
2
CNN
RD BR BR 24V
6
RD
F(3.15A)
2
BL
CNK1
CNT2
XB1
RD
+12
1
2
3
4
5
XB2
XB3
XB4
RD
BL
CNU
WH
BK
BK
BK
BK
BK
GR
RD
BK
BK
RD
RD
BK
RD
BK
Summary of Contents for 112KXE6
Page 105: ... 101 Model FDC335KXE6 A PCB003Z035 shows local wining ...
Page 134: ... 130 PJF012D003 ...
Page 135: ... 131 ...
Page 139: ... 135 PJA012D751 b ...
Page 140: ... 136 ...
Page 206: ... 202 2 model type DIS model type HEAD ...
Page 207: ... 203 2 2 ...
Page 208: ... 204 2 2 2 2 2 ...