1
18
-
Models FDK71KXE6
B
P
H
A
0
0
0
Z
9
8
4
I
I
I
I
I
I
I
I
I
I
BK
BL
BR
GN
Black
Blue
Brown
Green
P
WH
Y
Y/GN
Pink
White
Yellow
Yellow/Green
OR
Orange
RD
Red
5 or 6 wires
Fan motor(with thermostat)
Thermistor(Return air)
Thermistor(Heat exchanger)
Transformer
Louver motor
Thermistor(Remote controller)
LM
CNA〜Z
LED・3
LED・2
TB1
Fuse
Connector
Terminal block(□mark)
Th
C
Indoor unit address: tens place
SW1
Indoor unit address: ones place
SW2
Outdoor unit address: tens place
SW3
Outdoor unit address: ones place
SW4
Model capacity setting
SW6
Stepping motor
SM
TB2
Terminal block(Remote Controller)(□mark)
FM
Th −R1,2,3
Th −A
Tr
Indoor unit address: hundreds place
SW5−2
Automatic adjustment/Fixed previous
SW5−1
Operation check/Drain motor test run
SW7−1
F,F202
JSL1
Live Superlink terminal setting(for spare)
(for electronic expansion valve)
version of Superlink protocol
Indication lamp(Green−Normal operation)
Indication lamp(Red−Inspection)
Notes 1. indicates wiring on site.
2. Use twin core cord(0.75〜1.25mm
2
)at signal line between indoor unit and outdoor
unit, and signal line between indoor units.
3. Use twin core cord(0.3mm
2
)at remote controller line.
See spec sheet of remote controller in case that the total length is more
than 100m.
4. Do not put signal line and remote controller line alongside power source line.
XR1
XR2
XR3
XR4
XR5(Remote operation input:
Option
1
2
3
4
5
6
+12
BL
(Operation)
(Heating)
(Thermo On)
(Inspection)
Remote
Thc
t°
TB2
X Y
X Y
1
WH
3
M
M
220ー240V
WH
5
BK
3
4
2
19V
1
23V
M
t°
t°
t°
RD
5
3
1 2
4
WH
CNA2
SM
Control PCB
BK
WH
LED・2 LED・3
SW6
SW7
5
4
BK
3
1
2
1
2
3 4
Y
R
S
LM
6
5
WH
2 3 4
G
1
6
t°
5 6
2
1
XB1
XB2
XB3
XB4
For Heat recovery 3−pipe systems
1
2
3
4
5
+12
RD
(20S)
(SVH)
(SVG)
(SVE)
F202
(1A)
Power
6
B
A
N
L
RD
BL
BL
CNU
Power source line
between indoor units
Power
RD
WH
F
(3.15A)
RD
Y/GN
220ー240V〜50Hz
220V〜60Hz
Connector for branching
controller of heat recovery
3−pipe systems
WH
F
(3.15A)
Earth
TB1
TB1
Y/GN
Th
−R1 Th −R2
Th
−R3
Tr
Th
−A
FM
RD
CNT
CNB
CNW2
CNW1
CNA
CNH
CNK1
CNN
CNJ
CNM
CNT2
Superlink(spare)
JSL1
CNK2
volt−free contact)
controller
source line
WH
BK
BK
BK
BK
BK
BK
BK
BK
BL
P
BR
OR
RD
BK
BK
BR BR
WH
RD
RD
BK
WH
WH
Y
OR
BL
BR
RD
RD
BK
WH
Y
BL
circuit
RD
C
Signal line
CNL2
WH
WH
CNL1
SW1
SW2
SW4
SW3
SW5
between indoor units
Signal line
(Shielded cord)
WH
16V
Power source
(Single−phase)
Color Marks
Mark
Color
Mark
Color
Summary of Contents for 112KXE6
Page 105: ... 101 Model FDC335KXE6 A PCB003Z035 shows local wining ...
Page 134: ... 130 PJF012D003 ...
Page 135: ... 131 ...
Page 139: ... 135 PJA012D751 b ...
Page 140: ... 136 ...
Page 206: ... 202 2 model type DIS model type HEAD ...
Page 207: ... 203 2 2 ...
Page 208: ... 204 2 2 2 2 2 ...