123
-
(m) Duct Connected-Compact and Flexible type (FDUH)
Models All models
5 or 6 wires
X1
3
UH
WH
CNM3
C
1
X6
M
H
5
7
L
9
X3
X2
CNI
BL
WH
CNW1
220Vー240V
Tr
The terminal blocks
are for signal lines.
Do not connect power source
line (220V/240V/380V/415V ) with them.
Power source
TB1
WH
RD
220Vー240V〜 50Hz
Power Source
CNW0
WH
CNU
1
3
RD
RD
BL
N
L
X Y A B
LED・2
SW2
SW6
SW5
SW7
LED・3 SW1
SW3 SW4
F(3.15A)
F(3.15A)
Y/GN
CNW2
Earth
1
2
controller
Thc
t°
TB2
A B
X Y
X Y
1
3
CNK1
WH
CNB
WH
XR1
XR2
XR3
XR4
XR5(Remote operation input
Optional
1
2
3
4
5
6
+12
CNT
BL
(Operation)
(Heating)
(Inspection)
(Thermo ON)
Superlink(spare)
JSL1
※1
1
2
3
4
5
CNT2
RD
CNK2
when using CNK2(※1)
Cut the jumper(JSL1)
Control PCB
19V
24V
I
+12
(20S)
(SVH)
(SVG)
(SVE)
XB1
XB2
XB3
XB4
line
RD
WH
BK
BK
RD RD BR BR
: volt−free contact)
Remote
WH
BK
BL
RD
of heat recovery 3−pipe systems
Connector for branching controller
between indoor units
Power source line
For heat recovery
3−pipe systems
Signal line
between indoor units
Signal line
(Shielded cord)
BK
BK
WH
CNF1
I
CF
I
FM
M
1〜
Y/GN
BR
WH
BR
BK
BL
RD
1 2 3 4 5 6
CNA
RD
Th
I
−R1 Th
I
−R2 Th
I
−R3
Th
I
−A
t°
t°
1
2
3
4
CNN
5
6
1
2
t°
t°
M
BK
CNH
SM
WH Y OR BL BR RD
Y
RD
RD
OR
OR
BK
BK
BL
BL
WH
BR
BK
RD
I
CF
FM
Capacitor for FM
Fan motor(with thermister)
I
Indication lamp(Red−Inspection)
Indication lamp(Green−Normal operation)
LED・3
F
Fuse
LED・2
Connector
CNA〜Z
Live Superlink terminal setting(for spare)
JSL1
I
Indoor unit address: tens place
SW1
SM
Stepping motor
SW2
SW3
SW4
Indoor unit address: ones place
Outdoor unit address: tens place
Outdoor unit address: ones place
(For electronic expansion valve)
Model capacity setting
SW6
Operation check,Drain motor test run
TB2
Terminal block(Signal line)(□mark)
SW7−1
SW5−1
Automatic adjustment/Fixed
SW5−2
Indoor unit address: hundreds place
TB1
Terminal block(Power source)(□mark)
preivious version of Superlink protocol
Relay for FM
Thermistor(Remote controller)
Thermistor(Heat exchanger)
Thermistor(Return air)
Thc
Th
I
−R1,2,3
Th
I
−A
X1〜3,6
Tr
Transformer
I
Notes 1. indicates wiring on site.
2. Use twin core cable(0.75〜1.25mm
2
)at signal line between indoor unit
and outdoor unit, and signal line between indoor units.
3. Use twin core cable(0.3mm
2
) at remote controller line. See spec sheet
of remote controller in case that the total length is more than 100m.
4. Do not put signal line and remote controller line alongside power source line.
Color Marks
Mark
BK
BL
BR
OR
Color
Black
Blue
Brown
Orange
RD
WH
Y
Y/GN
Red
White
Yellow
Yellow/Green
GR
Gray
A
P
JC
0
0
1
Z
2
5
5
Summary of Contents for 112KXE6
Page 105: ... 101 Model FDC335KXE6 A PCB003Z035 shows local wining ...
Page 134: ... 130 PJF012D003 ...
Page 135: ... 131 ...
Page 139: ... 135 PJA012D751 b ...
Page 140: ... 136 ...
Page 206: ... 202 2 model type DIS model type HEAD ...
Page 207: ... 203 2 2 ...
Page 208: ... 204 2 2 2 2 2 ...