55
–
Error code
Remote controller:
7-segment display:
LED
Green
Red
Indoor
Outdoor
Content
WAIT
WAIT
(4)
Keeps flashing Stays Off
Keeps flashing Keeps flashing
1. Applicable model
5. Troubleshooting
All models
(In case that is kept
on displaying on the remote
controller for more than 2
minutes after power ON)
Diagnosis
Countermeasure
NO
Does
outdoor green LED keep
flashing?
is kept on
displaying on the remote
controller for more than 2
minutes after power ON
Does
indoor green LED keep
flashing?
Does
outdoor red LED flash
2 times?
Are
the wires between indoor
and outdoor units
connected properly ?
Is
AC380-415V detected
between L1-L2, L2-L3, L3-L1
respectively at outdoor
terminal block?
Is
AC220-240V detected
between L-N at indoor
teminal block?
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
A
WAIT
Refer next page
Indoor control PCB
anomaly
Replace it
Indoor control PCB
anomaly
Replace it
Remote controller anomaly
Replace it
Breakage of wires for
remote controller
Replace it
Correct the connecting
wires between indoor and
outdoor units
Outdoor control PCB
anomaly
Replace it
Breakage of connecting
wire
Noise
Indoor control PCB
anomaly
Replace it
2. Error detection method
3.
Condition of error displayed
4. Presumable cause
• Fuse blown
• Noise filter anomaly
• Anomalous connection of
wire between PCBs
• Indoor control PCB anomaly
• Remote controller anomaly
• Breakage of connecting wires
of remote controller
• Outdoor control PCB anomaly
Note:
WAIT
Summary of Contents for 112KXE6
Page 105: ... 101 Model FDC335KXE6 A PCB003Z035 shows local wining ...
Page 134: ... 130 PJF012D003 ...
Page 135: ... 131 ...
Page 139: ... 135 PJA012D751 b ...
Page 140: ... 136 ...
Page 206: ... 202 2 model type DIS model type HEAD ...
Page 207: ... 203 2 2 ...
Page 208: ... 204 2 2 2 2 2 ...