TROUBLE SHOOTING

Check the following items before requiring service.

THE UNIT DOES NOT WORK AT ALL

Is the power supply switch 
turned off?

Is there a blackout or is the 
fuse blown?

Is the leakage breaker 
activated?

Dangerous. Immediately turn 
off the power supply switch, 
and contact your dealer.

Is sunlight or other strong 
illumination striking the 
receive unit? (wireless unit)

ON

OFF

Is the air filter clogged?

Is the swing louver 
horizontal (during 
heating)?

If the swing 
louver is 
horizontal, the 
airflow may not 
reach down to 
the floor.

Are there any obstacles 
blocking the air inlet 
and outlet grill?

•  Is the direct daylight 

coming into the room?

• Are there any 

unexpected heat 
sources in the 
room?

•  Are there too many 

people in the room?

Is the unit in the 
heating preparation 
mode?

 

 See page 16

POOR COOLING OR HEATING

POOR COOLING

If, after checking the items above, the air conditioner still does not operate normally or in the next cases, stop operating and contact your dealer.
• 

If the fuse and breaker blow frequently. 

  If water drips at cooling/dehumidifying operation. 

• 

If the operation or operation noise is abnormal.

• 

If the check indicator light flashes.

The phenomena mentioned below is not malfunction.

NO AIRFLOW AT HEATING

 

HOW TO MAINTAIN

Air filter

tabs

 

When mounting, press the lever forward 
untill it snaps.

 

When morrting, snab the filter into the 
tabs of inlet grille.

 Ceiling suspended (FDE)

1.

 Slide the lever of the inlet grille 

backward 

(

  direction) and open it 

downwards.

2. 

Pressing the inlet grille, press the filter 
to remove it from the tab and pull it 
downwards.

Air filter is attached when the air conditioner is installed, so consult your dealer about 
how to remove or clean it.

 Duct connected −High static pressure− (FDU, FDUS)
 Duct connected −Middle static pressure− (FDUM)

MAINTENANCE OF THE UNIT

AT THE END OF THE PERIOD OF USE 
(after a long period of use)

AT THE BEGINNING OF THE PERIOD OF USE 
(after a long unused period)

• 

Clean the unit by wiping with a piece of soft and dry cloth. 
If the unit is very dirty, wipe it with a piece of cloth wet with 
neutral detergent dissolved in lukewarm water and wipe it 
off with clean water.

• 

Make sure to turn off the power supply.
The air conditioner consumes several tens of watts 
electricity even if it is stopped.

•  Clean the air filter and mount it.
•  Clean the indoor/outdoor units.

• 

Make sure that there is no object blocking the airflow 
around the inlet and outlet grille of the indoor/outdoor unit.

• 

Inspect the air filter. If it is dirty, clean and mount it.

• Turn on the power supply button for 

6

 hours before 

starting the operation.

How to clean

1

  Wash away for cleaning. If it is not so dirty, tap it or use 

cleaner.

 

If it is very dirty, dissolve some neutral detergent in lukewarm 
water (approximately 30°C), rinse the filter with it and wash 
the detergent away completely.

2

  After the air filter is dried, mount it to the main body and press 

RESET button.

ATTENTION 

• 

Do not dry by exposing the air filter to the direct sunlight or 
using fire. Otherwise, the filter may be damaged.

• 

Do not operate the air conditioner with the filter removed. 
Otherwise it may lead to trouble.

The air conditioning system 
sounds as if water is 
draining from it.

Sounds of rustling or gurgling may be heard when the operation is started, when the compressor is activated/
deactivated during operation, or when the operation is stopped. These are the sounds of the refrigerant 
flowing through the system.

Sounds of rustling or 
gurgling may be heard from 
a stopped indoor unit.

These sounds can be heard when the air conditioning system is performing automatic control.

The supply air from the 
indoor unit smells bad.

The supply air from the indoor unit may smell bad if the smell of cigarettes, cosmetics and/or furniture has 
saturated the air conditioning system.

White vapor is generated 
from the indoor unit during 
operation.

White vapor may be generated during operation if the system is used in environment where oils and fats are 
frequently used, such as in restaurants. In this case, consult the dealer and clean the heat exchanger.

The operation switched to 
fan operation during cooling 
operation.

The operation may switch to fan operation automatically in order to avald frost being built up on the surface of 
the heat exchanger. The operation will soon return to cooling operation.

The indoor fan does 
not stop even when the 
operation is stopped  in 
heating mode.

The indoor unit fan may continue operating for 40 seconds in order to remove remaining heat in the indoor 
unit.

CAUTION

 

Do not turn off the power supply until the fan stops.

The air conditioning system 
cannot start operating again 
immediately after stopping.

During the first 3 minutes after stopping operation, it is not possible to perform cooling, dehumidifying or 
heating operation even if the ON/OFF button is pressed to indicate “operation.” This is because a circuit for 
protecting the compressor is activated (the fan is operating during this period).

No air comes out during 
dehumidifying operation. 
The airflow volume cannot 
be changed.

During dehumidifying operation, the fan speed is automatically controlled in low speed/stop cycle in order to 
avoid both drastic temperature drop and humidity rise.

The swing louver moves 
without any operation.

The swing louver automatically swings twice when the power supply switch is turned on. This is not a trouble. 
The louver also moves automatically to the horizontal position when “PREPARATION OF HEATING” is 
displayed.

The outdoor unit discharges 
water or steam during 
heating operation.

Water or steam is discharge during defrosting operation which removes frost built up on the surface of the 
heat exchanger in the outdoor unit in heating mode.

The outdoor unit fan is not 
running even when the 
system is in operation.

The fan speed is automatically controlled according to the ambient temperature. It may be stopped in high 
ambient temperature in case of heating, and in low ambient temperature in case of coding. Also, the fan is 
stopped during defrosting operation.

CAUTION

 

The fan will suddenly begin to operate even if it is stopped. Do not insert finger and/or stick.

 Ceiling cassette −4 way Compact (600×600mm) − (FDTC)

1.

  Slide the inlet grille levers in the direction of the arrow (

), and 

open it downwards.

2.

  Release the inlet grille stopper.

3. 

Pull the filter towards you.

4. 

When the filter is put in place, insert the filter into the hooks on 
the inlet grille, and be sure to return the stopper to its original 
position.

5.

  When putting the inlet grille back in place, slide the levers in the 

opposite direction and check to be sure that the grille does not 
come open.

Hooks

Hooks

Stopper

PSA012B735_EN.indd   15

PSA012B735_EN.indd   15

2009-9-3   9:58:32

2009-9-3   9:58:32

Summary of Contents for AVANTI PLUS SRK25ZSXA-W

Page 1: ...ire cumple con la directiva EMC 2004 108 EC LV Directiva 2006 95 EC La indicación CE sólo corresponde al área de suministro eléctrico de 50 Hz Este aparelho de ar condicionado está em conformidade com a Directiva EMC 2004 108 EC a Directiva LV 2006 95 EC A marca CE aplica se à zona de fornecimento de energia a 50 Hz Το κλιματιστικό συμμορφώνεται προς την οδηγία 2004 108 ΕΚ περί ηλεκτρομαγνητικής σ...

Page 2: ...is mishandled Note however that depending on the situation the items listed in the CAUTION sections do also have the potential of causing serious outcomes Both warnings and cautions provide you important information related to safety please make sure to observe them The symbols used throughout the main text of this manual have the following meaning marks mean danger alarm and caution The specified...

Page 3: ...or checking indoor unit be sure to turn off Indoor unit power supply breaker It can result in electric shock or injury due to rotation of indoor unit fan if you perform check or repair with the Indoor unit power supply breaker turned on Place the panels removed for repairing or checking on the stable spot Otherwise dropping or falling may lead to injury CAUTION PRECAUTIONS FOR RELOCATION OR REPAIR...

Page 4: ... is not a malfunction In that case the operation of the button is prohibited When you start to operate for the first time after turning the power supply on the unit starts to operate as below You can change the setting as you like Central control Turned off Operation changeover With auto mode auto cooling Without auto mode cooling Set temperature 23 C Fan speed Louver position Horizontal ATTENTION...

Page 5: ... display If you press button while timer mode is operative timer mode is canceled and the display will return to the original display If you do not press any button for several minutes after entering the timer mode the timer mode ends and returns to the original display ATTENTION After certain period has elapsed the unit stops operating Sleep timer The unit stops operating at each setting time onc...

Page 6: ...h only ON timer or only OFF timer HOW TO PERFORM THE TIMER OPERATION WIRED REMOTE CONTROL 1 Press TIMER button 2 Press button for three times Æ Æ Æ 3 Press SET button EXAMPLE flashes lit 4 Press or button Set the preferred time to start the operation Set Hour If you press or button for a while Hour display is changed by one hour and stops when you stop pressing Set Minute If you press or button th...

Page 7: ...nd returns to the original display NOTICE HOW TO PERFORM THE TIMER OPERATION WIRED REMOTE CONTROL 5 Press SET button mark next to a number is switched to light or is displayed The settings so far are effective and the display changes as shown on the left 6 Press or button Press button and is displayed Press button and is displayed Select either of the above two Press the RESET button to return to ...

Page 8: ...day Setting HOW TO PERFORM THE TIMER OPERATION WIRED REMOTE CONTROL Weekly timer Holiday Setting It is possible to disable the timer settings temporarily which has been already set by applying Holiday Set on a particular day of the week When the Holiday Setting is cancelled the timer setting is enabled again 1 In the Weekly timer mode select and set See Selecting Weekly timer setting step 1 to 5 o...

Page 9: ...s SET button and silent setting is canceled ending the silent mode is displayed SILENT MODE Silent Mode Setting If you press button while silent mode is operative silent mode is canceled and the display will return to the original display Note that the setting which has not been completed is canceled HOW TO PERFORM THE TIMER OPERATION WIRED REMOTE CONTROL TIMER CACELLATION MODE 2 4 7 1 3 5 6 In ca...

Page 10: ...lect Other louver No settings have no effect 5 Press SET button Determination of louver No The louver No to be set is confirmed and the display shows the upper limit of the movable range EXAMPLE If No 1 louver is selected current upper limit position 6 Press or button selection of upper limit position Select the upper limit of louver movable range position 1 is the most horizontal and position 6 i...

Page 11: ...educed Moreover it leads to waste of electricity and larger operation noise It may cause failure Dew may form and drop during cooling Do not block the inlet and outlet grilles of the indoor and outdoor units Excessive load to the unit may cause failure Keep moderate room temperature Too much cooling or heating is not good for your health It will also waste the electricity Block direct sunlight and...

Page 12: ...onds when FILTER button is pressed OFF TIMER display Indicates when OFF TIMER is set See page 12 OPERATION MODE select button Every time this button is pressed displays switch as below AUTO COOL HEAT FAN DRY ROOM TEMP TIME SETTING button Sets room temperature by pressing or button Sets time when setting the time RESET switch Used to reset the microcomputer TIME SET UP switch Sets current time See ...

Page 13: ...r supply The crankcase heater is conducted while the compressor is stopped preventing failure of the compressor due to accumulation of liquid refrigerant by keeping the compressor warm The operation of remote control must be performed slowly and steadily HOW TO USE WIRELESS REMOTE CONTROL ATTENTION 4 1 5 3 2 AUTO COOL HEAT DRY FAN Guideline of room temperature setting COOL 26 to 28 C DRY 21 to 24 ...

Page 14: ...rror code symptom of the trouble air conditioner type and model name etc Press the ON OFF button to stay the air conditioner on the stop mode Light for 0 5 second wink out for 0 5 second Timer check indicator lamp WHEN LONG FLASHING LIGHT IS SHED FROM THE TIMER CHECK INDICATOR LAMP YELLOW Clean the filter See page 14 When cumulative running time reaches 120 hours long flashing light light for 2 se...

Page 15: ...ok on the grille E 2 places and push it securely until the filter is caught by the hook How to mount the grille 1 Hang the hook on the hole on the panel The hook on the grille can be hanged 3 sides on the panel 2 After the grille is hanged close the grille while the stopper on the grille 2 places is kept pressed to OPEN direction When the grille comes to the original position release the stopper t...

Page 16: ...started when the compressor is activated deactivated during operation or when the operation is stopped These are the sounds of the refrigerant flowing through the system Sounds of rustling or gurgling may be heard from a stopped indoor unit These sounds can be heard when the air conditioning system is performing automatic control The supply air from the indoor unit smells bad The supply air from t...

Page 17: ...place Are there any obstacles If so it leads to the decrease of the efficiency and the increase of operation noise Avoid the place where cool warm air and operation noise cause problems to your neighbors INSTALLATION LOCATION Normally the efficiency of the air conditioning system will become lower after a while because dirt accumulates inside the system This occurs gradually in around 3 years of u...

Reviews: