DRED
■
This air-conditioner complies with the DRED (Demand Response Enabling Devices) standard AS/NZS4755.3.1 and supports demand
response modes 1, 2 and 3 (DRM1, 2 and 3). Since the air-conditioner limits the electric power or energy by receiving the DRED input
signal, the sense of cooling operation or heating operation may deteriorate over time. The outdoor unit of this air-conditioner is equipped
with a terminal block for DRED input and supports ELV (Extra-Low Voltage) complying with AS/NZS60335.1.
Under DRED mode, RUN light and TIMER light blink alternately as shown. When the Defrost function becomes effective during DRED
operation, the TIMER light blinks quickly.
RUN light
ON
OFF
2 seconds
2 seconds
2 seconds
2 seconds
ON
OFF
TIMER light
Display in DRED mode
Display in DRED mode during Defrost operation
RUN light
ON
OFF
2 seconds
2 seconds
0.5 seconds
2 seconds
0.5 seconds
TIMER light
ON
OFF