−1−
−2−
Contents
Before use …………………………… 2
Safety precaution ……………………………… 2
Component replacement guide for maintenance
check and preventive maintenance …………… 10
Water quality criteria…………………………… 11
General description of CO
2
heat pump water heater … 12
Description of functions and contents of CO
2
heat pump water heater … 14
Names and functions of sections on the R/C … 16
Screen flow……………………………………… 18
Operation method of basic operation …… 20
Hot water operation method ………………… 20
How to Run/Pause …………………………… 21
Setting of HW temp for the operation to top up …… 22
Schedule setting ……………………………… 23
How to set operation pattern ………………… 24
How to set day off ……………………………… 27
How to set peak-cut …………………………… 29
How to check operation pattern ……………… 32
How to do the [Operation to fill up]…………… 33
How to set to increase or decrease the
hot water amount uniformly…………………… 34
Display usage of hot water amount ………… 35
Display of operation mode …………………… 35
Operation method of menu manipulation …… 36
Limited items for sub remote control ………… 36
How to operate on the menu screen ………… 37
How to operate on the menu screen ………… 38
Notabilia for each setting screen …………… 38
Operation method of various settings …… 39
How to set [Initial settings] …………………… 39
How to set Administrator settings …………… 42
How to check the remote control setting …… 49
For maintenance …………………… 50
Maintenance of remote control,
heat pump unit and hot water storage unit … 50
Measure for anti-freeze water in winter……… 51
When stopping the unit for long period ……… 51
When power failure occurs …………………… 51
When error happens ………………… 52
Notice of next service date ………… 56
When the [Periodical check]
is displayed …………………………… 57
After-sales Service…………………… 57
Specifications ………………………… 58
EC DECLARATION OF CONFORMITY…… 59
●
In order to protect the heat pump unit,
be sure to turn the power on at least 6
hours before starting operation. (Supply
the power to the crankcase heater and
warm up the compressor) And do not
turn the power off when stopping.
(During stopping of compressor, the
crankcase heater is kept energized for
the compressor to be kept warm in
order to prevent compressor from
breakdown due to the migration of liquid
refrigerant in the compressor.)
●
If the ambient air temperature becomes
below 0°C, the water pipe may freeze.
It may cause break of the water pipe
and the heat pump unit.
Please consult with the dealer and take
proper measure for anti-freezing water.
If water may freeze, be sure to keep the
power turning on during Pause as well.
This unit has a function to start anti-freeze
operation during Pause, when water
may freeze.
●
If do not use hot water for one month or
more, be sure to shut off the main power
and drain off the water in the heat
pump unit and the unvented cylinders.
When power failure happens and the
water may freeze, be sure to drain off
immediately.
Regarding the way to drain off, please
consult with the installer or the dealer.
Note