101
-
'12 • PAC-T-173
Pipe
c
Fan unit
View M
tapping screws
Holes for
Remote controller
㧔
Option
㧕
Return air duct
Drain hose piece
㧔
Accessory
㧕
㧔
Installed on site
㧕
Hole
tapping screw
Holes for
A
Gas piping
B
Liquid piping
C1
Drain piping
VP20
standard:I.D.20, O.D.26
or VP25
Used with attached
socket:I.D.25, O.D.34
Note
2
D
Hole for wiring
E
Suspension bolts
M10
F
Outside air opening
Air outlet opening
G
Symbol
Content
Ǿ
12.7
1
㧛
2"
Flare
for ducting
for ducting
Ǿ
150
Knock out
Ǿ
125
Knock out
Drain piping
C2
㧔
Gravity drainage
㧕
VP20
standard:I.D.20, O.D.26
or VP25
Used with attached
socket:I.D.25, O.D.34
Ǿ
6.35
1
㧛
4"
Flare
㧕
H
Inspection hole
450X450
Ǿ
170
Ǿ
124
Ǿ
170
tapping screws
Holes for
Space for installation and service
or more
or more
or more
or more
㧔
Case 1
㧕
From side of unit
or more
or more
㧔
Case 2
㧕
From bottom of unit
Notes
a
There must not be obstacle to draw
out fan unit. For fan unit maintenance,
refer to page 229.
b
Install refrigerant pipes,
drain pipe,and wiring so as
not to cross marked area.
c
The case that pipes are installed to upper
bottom
of fan unit,
keep space of 60mm or more to upper
bottom
of unit.
4
㧙Ǿ
4
㧔
Suspension bolts pitch
㧕
Air supply duct
Control box
600
㧔
Max. drain lift
㧕
or less
㧔
Duct dimension
㧕
㧔
Duct dimension
㧕
43
170
28
472
135
18
750
18
786
suspension bolt
Hanger plate for
55
680
55
76
67
58
81
284
152
262
41
200
39
65
660
65
139
غ
90
46
200
200
46
200
31
170
31
12
㧙Ǿ
4
19
غ
120
280
467
413
471
510
635
30
30
105
175
250
㧔
Duct dimension
㧕
㧔
Duct dimension
㧕
69
295
㨪
325
113
4
㧙Ǿ
4
1000
150
㨪
200
100
㨪
200
100
Slab
20
20
Note
a
370
Ceiling
Note
b
600
1100
100
Inspection
hole
620
Note
a
Unit:mm
15
50
㧔
Suspension bolts pitch
㧕
F
G
M
E
C
2
D
A
1
C
B
G
F
H
Notes
1
The model name label is attached on the lid of
the control box.
2
Prepare the connecting socket
VP20 or VP25
on site.
Select either of two cases to keep space for installation and services.
(e) Duct connected-Low / Middle static pressure type (FDUM)
Model FDUM50VF
A
PJG000Z002
Summary of Contents for FDC Series
Page 95: ... 94 12 PAC T 173 Models FDT100VF 125VF 140VF H H H H H C B A F G D G PJF000Z285 ...
Page 98: ... 97 12 PAC T 173 Models FDEN60VF 71VF C 2 C 1 A B A B D C 1 C 2 C 1 C 2 E G F B PFA003Z817 ...
Page 113: ... 112 12 PAC T 173 b Wireless remote controller RCN E1R 60 17 150 Unit mm ...
Page 278: ... 277 12 PAC T 173 ー K ...
Page 346: ... 345 12 PAC T 173 Power PCB 1BSU OVNCFS 4GRNCEG VJG 2 ...
Page 518: ... 517 12 PAC T 173 3 5 SUPER LINK E BOARD SC ADNA E F SL2NA E and SL3N AE BE to control ...
Page 519: ... 518 12 PAC T 173 ...