288
-
'12 • PAC-T-173
2-1
DIS-WA1
Supported combinations
Outdoor unit model Indoor unit model
6HP
2HP
+
2HP
+
2HP
Supported combinations
Outdoor unit model Indoor unit model
10HP
8HP
3HP
+
5HP
4HP
+
4HP
5HP
+
5HP
Joint C
ID9.52
ID9.52
ID9.52
①
③
②
Supported combinations
Outdoor unit model
Indoor unit model
3HP
+
3HP
+
3HP
8HP
1.5HP
+
1.5HP
3HP
6HP
5HP
4HP
3HP
+
3HP
2.5HP
+
2.5HP
2HP
+
2HP
1.5HP
+
2.5HP
2HP
+
3HP
2HP
+
4HP
Connecting pipe
(
φ
9.52)
ID9.52
ID9.52
①
②
③
Flare joint
(
φ
6.35)
Joint A
CAUTION
Reference
Connecting pipe
(
φ
9.52)
ID9.52
ID9.52
①
②
③
Flare joint
(
φ
6.35)
Joint A
Joint B
ID15.88
①
②
③
ID12.7
ID15.88
CAUTION
Reference
2-3
DIS-TA1
Applicable to the difference in length of pipes after the branch being less than 3 m
* Connection is not allowed when the difference in length of pipes is larger than 3 m.
Applicable to the difference in length of pipes after the branch being less than 3 m
* Connection is not allowed when the difference in length of pipes is larger than 3 m.
When the difference in length of pipes after the branch is longer than 3 m and shorter than 10 m
2-5. Triple type for same model/same capacity or different model/same capacity
Outdoor unit
Indoor unit
a
b
Branching pipe
Indoor unit model
Outdoor unit model
Branching pipe set type
Liquid branching pipe
Gas branching pipe
ID9.52
①
②
③
Connecting pipe
(
φ
9.52)
Flare joint
(
φ
6.35)
Flare joint
(
φ
6.35)
Joint A
Joint A
CAUTION
Reference
Connecting pipe
(
φ
9.52)
ID9.52
ID9.52
①
②
③
Flare joint
(
φ
6.35)
Joint A
Joint B
ID15.88
①
②
③
ID12.7
ID15.88
CAUTION
Reference
Joint B
ID15.88
①
②
③
ID12.7
ID12.7
Joint B
2HP
+
2HP
+
2HP
a
DIS-WA1
6HP
b
3HP
+
3HP
+
3HP
a
DIS-WB1
8HP
b
DIS-WA1
ID9.52
ID9.52
ID9.52
①
②
③
ID25.4
①
②
③
ID15.88
ID15.88
ID15.88
①
②
ID15.88
ID15.88
③
ID9.52
Connecting pipe
(
φ
9.52)
Joint A
Joint A
Flare
joint
(
φ
6.35)
Reference
②
③
④
①
CAUTION
2-4
DIS-TB1
Liquid branching pipe
Gas branching pipe
Liquid branching pipe
Gas branching pipe
Liquid branching pipe
Gas branching pipe
2-2
DIS-WB1
ID12.7
ID9.52
ID9.52
①
②
③
ID25.4
①
②
③
ID15.88
ID15.88
ID25.4
①
②
③
ID15.88
ID15.88
③
④
ID9.52
ID9.52
①
②
ID15.88
①
② ③ ④
ID12.7
ID25.4
①
② ③ ④
ID15.88
ID9.52
①
②
③
Connecting pipe
(
φ
9.52)
Flare joint
(
φ
6.35)
Flare joint
(
φ
6.35)
Joint A
Joint A
Joint B
ID15.88
①
②
③
ID12.7
ID12.7
Joint B
Joint B
ID15.88
①
②
③
ID12.7
ID12.7
Joint B
Joint B
ID15.88
①
②
③
ID12.7
ID12.7
Joint B
Joint B
ID15.88
①
②
③
ID12.7
ID15.88
Joint B
ID15.88
①
②
③
ID12.7
ID15.88
CAUTION
Reference
Gas branching pipe
Supported combinations
Liquid branching pipe
Outdoor unit model Indoor unit model
ID9.52
ID9.52
ID9.52
①
②
③
ID15.88
①
②
ID15.88
ID15.88
③
ID15.88
①
②
ID15.88
ID15.88
③
Joint C
ID9.52
ID9.52
ID9.52
①
③
②
A
A
Note When connect the indoor unit of an old model that is shown in the model list,
use the joint supplied with the branch piping set like A
OLD Model list
model name
FDTA251R
FDENA251R
FDKNA251R
FDURA251R
FDUMA252R
Summary of Contents for FDC Series
Page 95: ... 94 12 PAC T 173 Models FDT100VF 125VF 140VF H H H H H C B A F G D G PJF000Z285 ...
Page 98: ... 97 12 PAC T 173 Models FDEN60VF 71VF C 2 C 1 A B A B D C 1 C 2 C 1 C 2 E G F B PFA003Z817 ...
Page 113: ... 112 12 PAC T 173 b Wireless remote controller RCN E1R 60 17 150 Unit mm ...
Page 278: ... 277 12 PAC T 173 ー K ...
Page 346: ... 345 12 PAC T 173 Power PCB 1BSU OVNCFS 4GRNCEG VJG 2 ...
Page 518: ... 517 12 PAC T 173 3 5 SUPER LINK E BOARD SC ADNA E F SL2NA E and SL3N AE BE to control ...
Page 519: ... 518 12 PAC T 173 ...