88
CHANGE FLAP DIRECTION
CHANGE THE FAN SPEED
F1/F2 SWITCH OPERATION
1
Tap the Change
fl
ap direction button on the TOP screen.
2
When the Change set temp screen is displayed, select the
temperature as desired with using
buttons.
3
After selecting the set temp, tap the
Set
button. The
display returns to the TOP screen.
For allowable temperature setting ranges, refer to the range
setting of set temp.
Reference set temp
Cooling
… 26 to 28°C
Dry
… 24 to 26°C
Heating
… 20 to 24°C
Fan
… Setting temp is not required.
If the Auto is selected for the set temp, the set temp display shows “0”.
Temperature can be adjusted higher or lower with using
buttons.
Note that Auto is not displayed and cannot be set when SC-SL2, SC-SL3,
or SC-SL4 is connected.
If the Back button is tapped without tapping the
Set
button, the
selected set temp is invalidated and the display returns to the TOP screen.
Change set temp
Auto
Set
Back
Outdoor
Room
R/C
Tap
▲▼
to set temp & tap [Set].
2
The Change
fl
ap direction screen is displayed.
To swing the louver, tap the Swing button.
To
fi
x the louver position, swing the louver, and tap the
Stop
button at the desired position.
After the
fl
ap direction is selected, the display returns to the
TOP screen.
Swing
Stop
Changing the function of the F1 or F2 switch can be performed with the F1/F2 function setting.
The following functions are set as factory settings.
You may change these settings as desired.
F1 switch …High power operation
F2 switch …Energy-saving operation
You can set any of the following functions to the F1 and F2 switches.
The F1 / F2 switches act as shortcuts; it can be much easier and faster than starting an operation from the
usual Menu on the TOP screen.
•
High power operation
…
☞
page 9
•
Energy-saving operation
…
☞
page 9
•
Silent mode control
…
☞
page 22
•
Favorite setting operation
…
☞
page 22
•
Filter sign reset
…
☞
page 23
1
Tap the Change the fan speed
button on the TOP screen.
2
When the Change the fan speed screen is displayed, tap the
button of desired fan speed.
After setting the fan speed, the display returns to the TOP screen.
Fan speeds which can be set vary depending on the models of IU.
When the Auto is selected, the fan speed is changed automatically
depending on the capacity.
Note
that Auto is not displayed and cannot be set when SC-SL2 or
SC-SL3 is connected.
Change the fan speed
Back
Outdoor
Room
R/C
Select the fan speed.
Auto
•
If you forcibly move the swing louver mechanism by hand, it may be damaged, so do not move it by hand.
Advice
PGA012A413_EN.indd 8
PGA012A413_EN.indd 8
2022/6/23 13:25:30
2022/6/23 13:25:30