9
HIGH POWER OPERATION
ENERGY-SAVING OPERATION
The high power operation adjusts the room temperature quickly to a pleasant level by increasing the operation
capacity.
The high power operation continues for 15 minutes at the maximum and returns to the normal operation
automatically. When the operation mode is changed, the high power operation returns to the normal operation, too.
High power operation must be set to the F1 or F2 switch.
High power operation is set to the F1 switch as the factory setting.
1
Push the F1 ( F2 ) switch to start the high power operation.
Operation will start when the F1 ( F2 ) switch is pushed, even if
Run/Stop
switch is off.
High power operation is only allowed when Heating or Cooling is selected
for the operation mode.
Message “In operation for high power.” is displayed on the R/C
screen, and “—, —°C” is displayed on the Set temp button
during the high power operation.
Set temp and change fan speed operations are disabled during high
power operation.
2
High power operation is terminated when you perform one of
the following.
•
When you terminate through a Run/Stop operation
•
When you change the operation mode
•
When15 minutes have elapsed since the high power
operation started
•
When you terminate the high power operation with the
F1 ( F2 ) switch
Menu
Direction
Cooling
15 : 50 (Mon)
F1: High power
Timer
In operation for high power.
Set temp
F2: Energy-saving
1
Push the F1 ( F2 )switch to start the energy-saving
operation.
Operation will start even if you press the F1 ( F2 ) switch while the
unit is stopped.
Energy-saving operation is only allowed when Heating, Cooling or Auto is
selected for the operation mode.
Message “In operation for energy-saving.” is displayed on the
screen during the energy-saving operation. Set temp is
fi
xed at
“28.0°C” in the cooling operation or “22.0°C” in the heating
operation. Set temp shows “- -°C” in the automatic operation
mode.
Set temp cannot be changed during the energy-saving operation. If it is
attempted, a message “Invalid request” is displayed on the screen.
2
Energy-saving operation is terminated when you perform the
following.
•
When you terminate through a Run/Stop operation
•
When you change the operation mode
•
When you terminate the energy-saving operation with the
F1 ( F2 ) switch
Use this operation to save energy. Set temp is
fi
xed at 28°C in the cooling operation or 22°C in the heating
operation. Since the capacity is controlled automatically based on the outdoor temperature, energy can be saved
without losing comfort.
Energy-saving operation must be set to the F1 or F2 switch.
Energy-saving operation is set to the F2 switch as the factory setting.
Menu
Direction
Auto
16 : 04 (Mon)
F1: High power
F2: Energy-saving
Timer
In operation for energy-saving.
Set temp
PGA012A413_EN.indd 9
PGA012A413_EN.indd 9
2022/6/23 13:25:30
2022/6/23 13:25:30