'14 • KX-SM-200
E31
E32
E36
E37
E38
E39
E40
E41
E42
E43
E44
Duplicated heat source unit address No.
Open L Phase on power source at primary side
Discharge pipe temperature error
Outdoor air temperature thermistor anomaly
Discharge pipe temperature thermistor anomaly
High pressure anomaly
Power transistor overheat
Current cut
Anomaly contents
Anomalous stop of master heat source unit Anomalous stop of slave heat source unit
System stop
Unit stop
System stop
Unit stop
Remote control
error display
Heat source unit heat exchanger and subcooling
coil temperature thermistor anomaly
Liquid flooding anomaly
Excessive number of indoor unit connected,
excessive to tal capacity of connection
E45
E46
E49
E51
E53
E54
E55
E56
E59
E60
E61
E63
Mixed address setting methods coexistent in same network
Mixed address setting methods coexistent in same network
Low pressure error
Suction pipe temperature thermistor anomaly
Under-dome temperature thermistor anomaly
Power transitor temperture thermistor anomaly
Compressor startup failure
Rotor position detection failure
Emergency stop
Communication error between inverter
PCB and heat source unit control PCB
High pressure sensor/Low pressure
sensor anomaly
Power transister overheat (continuousness)
Communications error between the master
unit and slave units
Backup operation function is only for emergency purpose when one of compressors or one of units is damaged.
If backup operation is performed continuously for long period, it may cause the damage of good compressors.
Accordingly be sure to repair the damaged unit or to replace the damaged compressor and to cancel the
backup operation within 48 hours after starting backup operation.
(c) Prohibiting conditions of auto backup operation
(i) When the conditions of oil return control are not established
(ii) When the backup operation time has exceeded the limit value
(d) Control after the conditions to prohibit the auto backup operation have been established
All compressor stop, and the error display [E-XX] is shown on the -segment display and the remote control.
In this state, the inspection reset of remote control is effective.
→
[E-XX] is displayed continuously on the remote con-
In this state, the inspection reset of remote control is effective.
→
[E-XX] is displayed continuously on the remote con-
trol.
E45
E49
E51
E53
E54
E55
E56
E59
E60
E61
E63
E58
Low pressure error
Suction pipe temperature thermistor anomaly
Under-dome temperature thermistor anomaly
Power transitor temperture thermistor anomaly
Anomalous compressor by loss synchronism
Anomalous compressor by loss synchronism
Compressor startup failure
Rotor position detection failure
Emergency stop
High pressure sensor/Low pressure
sensor anomaly
Power transister overheat (continuousness)
Communications error between the master
unit and slave units
Backup operation function is only for emergency purpose when one of compressors or one of units is damaged.
If backup operation is performed continuously for long period, it may cause the damage of good compressors.
Accordingly be sure to repair the damaged unit or to replace the damaged compressor and to cancel the backup operation
within hours after starting backup operation.
(c) Prohibiting conditions of auto backup operation
(i) When the conditions of oil return control are not established
※1:
It cannot operate because all indoor units become in anomalous condition.
(ii) When the backup operation time has exceeded the limit value
(iii) When the -way valve is switched on any indoor unit
(d) Control after the conditions to prohibit the auto backup operation have been established
All compressor stop, and the error display [E-XX] is shown on the -segment display and the remote control.
trol.
E64
No water pump start input
Anomalous stop by the anti-freeze protection
No water pump start input
Anomalous stop by the anti-freeze protection
E46
※1
※1
※1
※1
E58
E64