'14 • KX-SM-204
-
21
-
Code
No.
Remarks
See table on P.55
See table on P.54
Only displaying
Displays No. of the protection control of which effect is the strongest
among those occurred from the start of operation after the power on.
Displays No. of the protection control of which effect is stronger thirdly
among those occurred from the start of operation after the power on.
Displays No. of the error detection of which effect is the strongest among
those occurred from the start of operation after the power on.
Displays No. of the error detection of which effect is stronger secondly
among those occurred from the start of operation after the power on.
Displays No. of the error detection of which effect is stronger thirdly
among those occurred from the start of operation after the power on.
Displays No. of the protection control of which effect is stronger secondly
among those occurred from the start of operation after the power on.
Contents of display
Data display
range
Minimum
unit
C59
C60
C61
C65
C66
C67
C68
C69
C70
C71
C72
C73
C74
C75
C80
C81
C82
C83
C84
C85
C86
C87
C88
C89
C90
C91
C92
0~999
0~100
0~127
0~127
0~127
0~255
0~127
0~127
10min
1%
1
1h
1
FMo1 operating revolution command
Control status
Protection control status
Compressor stop causes
Time elapsed after compressor stop cause
Protection control causes 1
Compressor error causes 1
Counter · Anomalous FMo1
Counter · Anomalous FMo2
Counter · Indoor-outdoor communications error
-1
FMo2 operating revolution command
0~999
10min
-1
Demand ratio
Outdoor operating mode pattern
0~127
1
1
1
Protection control causes 2
1
Protection control causes 3
0~127
1
0~127
1
Compressor error causes 2
0~127
1
Compressor error causes 3
0~127
1
Counter · Current cut (CM1)
0~255
0~255
1
1
EEPROM memory. Resettable.
Counter · Current cut (CM2)
Counter · Power transistor overheat (CM1)
Counter · Power transistor overheat (CM2)
Counter · Compressor startup failure (CM1)
Counter · Compressor startup failure (CM2)
Counter · Anomalous compressor by loss of
synchronism (CM1)
Counter · Anomalous compressor by loss of
synchronism (CM2)
Counter · Communication error between inverter
PCB and outdoor control (CM1)
Counter · Communication error between inverter
PCB and outdoor control (CM2)
0~255
0~255
0~255
0~255
0~255
0~255
0~255
0~255
0~255
0~255
0~255
1
1
1
1
1
1
1
1
1
1
—
EEPROM memory. Resettable.
EEPROM memory. Resettable.
EEPROM memory. Resettable.
EEPROM memory. Resettable.
EEPROM memory. Resettable.
EEPROM memory. Resettable.
EEPROM memory. Resettable.
EEPROM memory. Resettable.
EEPROM memory. Resettable.
EEPROM memory. Resettable.
EEPROM memory. Resettable.
EEPROM memory. Resettable.
C93
0~255
—
Counter · CPU reset