'14 • KX-SM-204
-
30
-
Code
No.
Contents
Write-in contents
Data write-in
range
Number of
bytes
Write-in unit
Record data
84
85
1
87
1
Protection control status 3
—
—
Bit0
Bit1
0: Normal
1: Practice
0
1
2
3
4
5
6
7
Normal
Insufficient check operation start condition
Check operation warm-up
Check operation ON
Check operation stop
Operation valve is closed
Indoor unit abnormal
Normal ending of check operation
HP protection 1
0~127
—
1
Protection control status 1
Control status
Refrigerant quantity check
Compressor capacity control
—
Gas bypass control
HP protection 3
Heating stop indoor unit slight opening control
LP protection 1
Compressor capacity control
LP protection 2
Compressor rising rate control
LP protection 3
Outdoor unit EEV control
LP protection 4
Oil separator SV control
Td protection 1
HP protection 2
Compressor capacity control
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
Bit2
Bit3
Bit4
Bit6
Bit7
0: Normal
1: Practice
0: Normal
1: Practice
Spare
0: Normal
1: Practice
Spare
79
1
Control status 3
Bit0
Auto backup operation
—
—
Bit1
Bit2
Bit3
Bit4
Bit5
Bit6
Bit7
Spare
Spare
Spare
Spare
0: Count
1: Count up
Spare
Spare
Spare
0: Normal
1: Practice
0: Count
1: Count up
0: Count
1: Count up
0: Count
1: Count up
0: Count
1: Count up
0: Count
1: Count up
0: Count
1: Count up
81
0~127
1 hour
1
Backup cumulative time
82
0~2
—
1
Check operation status
83
Spare
Bit0
Bit1
Bit2
Bit3
Bit4
Bit5
Bit6
Bit7
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
Td protection 2-1
EEVSC-Td cooling control
EEVH-Td cooling control
Td protection 4
Heating stop indoor unit slight opening control
Td protection 5
Outdoor unit EEV control
CS protection 1
Compressor capacity control
Tc protection 1
Compressor capacity control
Tc protection 2
Gas bypass control
Tc protection 3
Td protection 2-2
CM dilution protection control
Bit0
Bit1
Bit2
Bit3
Bit4
Bit5
Bit6
Bit7
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
86
1
Protection control status 2
—
CM protection 1
Compressor capacity control
CM protection 2
Outdoor unit EEV control
Compressor capacity control
PT protection 2
Inverter cooling fan control
Dilution rate protection
PT protection 1
88
1
Protection control causes 1
—
0~127
89
1
Protection control causes 2
—
0~127
—
—