77
-
Models FDK71KXE6
XR1
XR2
XR3
XR4
Option
1
2
3
4
5
6
+12
CNT
BL
X
Y
X
Y
1
CNB
WH
3
M
M
CNW2
CNW1
WH
5
BK
3
4
2
1
M
t
.
t
.
t
.
B
A
N
L
RD
BL
BL
CNU
RD
5
3
1
2
CNA
4
WH
CNA2
SM
BK
CNH
WH
CNK1
SW6
SW7
5
4
BK
3
1
2
1
2
3
4
Y
R
S
CNN
LM
CNJ
RD
WH
RD
6
5
WH
2
3
4
CNM
G
1
Y/GN
6
t
.
5
6
2
1
XB1
XB2
XB3
XB4
1
2
3
4
5
+12
CNT2
RD
WH
F202
(1A)
6
TB2
TB1
TB1
Y/GN
FMI
JSL1
CNK2
RD
BK
BK
BK
BK
BK
BK
BK
BK
BL
P
BR
OR
RD
BK
WH
WH
Y
OR
BL
BR
RD
RD
BK
WH
Y
BL
RD
WH
C
CNL2
WH
WH
CNL1
SW1
SW2
SW4
SW3
SW5
220-240V
19V
23V
BK
BK
BR
BR
WH
RD
RD
WH
16V
LM
CNA~Z
LED.3
LED.2
TB1
SW1
SW2
SW3
SW4
SW6
SM
TB2
FMI
SW5-2
SW5-1
SW7-1
JSL1
Connector
Fuse
Live Superlink terminal setting (for spare)
Indication lamp (Green-Normal operation)
Indication lamp (Red-Inspection)
Louver motor
Stepping motor
(for electronic expansion valve)
Indoor unit address : tens place
Indoor unit address : ones place
Outdoor unit address : tens place
Outdoor unit address : ones place
Automatic adjustment/Fixed previous
version of Superlink protocol
Indoor unit address : hundreds place
Model capacity setting
Operation check, Drain motor test run
Terminal block (
□
mark)
Thermistor (Remote controller) (
□
mark)
Meaning of marks
Fan motor (with thermostat)
Thermistor (Return air)
Thermistor (Remote controller)
Thermistor
Thermistor (Heat exchanger)
ThI-A
ThI-R1,2,3
Thc
TrI
1. indicates wiring on site.
2.Use twin core cord (0.75~1.25mm
2
) at signal line between indoor unit and
outdoor unit, and signal line between indoor units.
3.Use twin core cord (0.3mm
2
) at remote controller line. See spec sheet of remote
controller in case that the total length is more than 100m.
4.Do not put signal line and remote controller line alongside power source line.
Notes
Black
Blue
Brown
Green
Orange
Pink
Red
White
Yellow
Yellow/Green
Mark
Color
Mark
Color
BK
BL
BR
P
RD
WH
Y
Y/GN
OR
GN
Color marks
F,F202
Power source
(Single-phase)
220-240V~50Hz
220V~60Hz
Power source
line
Power source line
between indoor units
Earth
Connector for branching
controller of heat recovery
3-pipe systems
F(3.15A)
F(3.15A)
Signal line
(Shielded cord)
Signal line
between indoor units
ThI-R1
ThI-R2
ThI-R3
ThI-A
Power
circuit
Superlink (spare)
LED
•
2
LED
•
3
Tr I
Control PCB
t
.
Remote
controller
Thc
XR5 (Remote operation input:
volt-free contact)
For Heat recovery 3-pipe systems
(Operation)
(Heating)
(Thermo ON)
(Inspection)
(20S)
(SVH)
(SVG)
(SVE)
Summary of Contents for FDC112KXEN6
Page 116: ... 112 4 Sensible heat capacity ...
Page 117: ... 113 ...
Page 118: ... 114 ...
Page 119: ... 115 ...
Page 120: ... 116 ...
Page 121: ... 117 ...
Page 122: ... 118 ...
Page 123: ... 119 ...
Page 124: ... 120 ...
Page 125: ... 121 ...
Page 126: ... 122 ...
Page 127: ... 123 ...
Page 128: ... 124 ...
Page 129: ... 125 ...
Page 130: ... 126 ...
Page 131: ... 127 ...
Page 132: ... 128 ...
Page 133: ... 129 ...
Page 134: ... 130 ...
Page 135: ... 131 ...
Page 136: ... 132 ...
Page 137: ... 133 ...
Page 138: ... 134 ...
Page 139: ... 135 ...
Page 140: ... 136 ...
Page 141: ... 137 ...
Page 142: ... 138 ...
Page 143: ... 139 ...
Page 144: ... 140 ...
Page 145: ... 141 ...
Page 146: ... 142 ...
Page 147: ... 143 ...
Page 148: ... 144 ...
Page 149: ... 145 ...
Page 150: ... 146 ...
Page 151: ... 147 ...
Page 152: ... 148 ...
Page 153: ... 149 ...
Page 154: ... 150 ...
Page 155: ... 151 ...
Page 156: ... 152 ...
Page 157: ... 153 ...
Page 158: ... 154 ...
Page 159: ... 155 ...
Page 160: ... 156 ...
Page 161: ... 157 ...
Page 162: ... 158 ...
Page 163: ... 159 ...
Page 164: ... 160 ...
Page 165: ... 161 ...
Page 166: ... 162 ...
Page 167: ... 163 ...
Page 168: ... 164 ...
Page 169: ... 165 ...
Page 170: ... 166 ...
Page 171: ... 167 ...
Page 172: ... 168 ...
Page 173: ... 169 ...