–
–
'14 • KX-SM-221
-
9
-
Code
No.
Contents
Write-in contents
Data write-in
range
Number of
bytes
Write-in unit
Record data
0
100
Dehumidifying stop 0-speed
110
Dehumidifying operation 0-speed
Air inlet temp.
Heat exchanger temp. 1
00
01
02
03
04
05
06
-10~52
-19~71
0~500
1
1
1
1
2
1
2
Indoor unit 1 Thi-A
Indoor unit 1 Thi-R1
Indoor unit 1 Thi-R2
Indoor unit 1 Thi-R3
Indoor unit 1 EEV
Indoor unit 1 setting temperature
Indoor unit 1 Operation mode/Air capacity
-19~71
-19~71
1pulse
0~470
0~127
−
Heat exchanger temp. 2
Heat exchanger temp. 3
05H command
Not used (Data not received)
111
112
Dehumidifying operation 2-speed
113
Dehumidifying operation 3-speed
Dehumidifying operation 1-speed
114
115
Dehumidifying operation 5-speed
116
Dehumidifying operation 6-speed
Dehumidifying operation 4-speed
200
210
Cooling operation 0-speed
211
Cooling operation 1-speed
Cooling stop 0-speed
212
213
Cooling operation 3-speed
214
Cooling operation 4-speed
Cooling operation 2-speed
215
216
Cooling operation 6-speed
300
Fan stop 0-speed
Cooling operation 5-speed
310
311
Fan operation 1-speed
312
Fan operation 2-speed
Fan operation 0-speed
313
314
Fan operation 4-speed
315
Fan operation 5-speed
Fan operation 3-speed
316
400
Heating stop 0-speed
410
Heating operation 0-speed
Fan operation 6-speed
(b) Saving of Operation Data
For the purpose to investigate the cause of trouble in the field
, the operation data are always saved in the memory, and if the trouble
occurs, the data writing is stopped and the operation data prior to the trouble occurrence are recorded. These data can be retrieved to
personal computer through RS232C connector on the outdoor control PCB and utilized for investigating the cause.
(i) Operation data for a period of 30 minutes prior to the present operation are saved and updated sequentially.
(ii) If an anomalous stop occurs, the data are not updated any more.
(iii) Data are written in at 1-minute interval and following data will be transmitted to PC upon demand.
Data
Software version
PID (program ID)
Outdoor unit capacity
Power source frequency
Outdoor address
Indoor address × 16 units
Indoor capacity × 16 units
Ascii 15 byte
Ascii 2 byte
Ascii 3 byte
Ascii 2 byte
Ascii 2 byte
Ascii 2 byte × 16 units
Ascii 3 byte × 16 units
KD3C218######## (#: NULL)
5D
As shown in table at right
60
00 ~ 3F
40 ~ 7F
022 ~ 280
Data Range
Example
Outdoor unit capacity data
Remarks
Outdoor unit capacity data
S: Display with Horse Power of single type or
single use of combination type
Single type
Example: 24HP - [S24]
(iv) Error retention and monitoring data
< Indoor unit indicate data >
1°C
1°C
1°C
1°C
0.5°C
'14 • KX-SM-221