-
20
-
'09•KX-T-139
Gas pipe: 31.8
0
0.80
0.85
0.90
0.95
1.00
20
40
60
80
100
90
120 140 160 180
Capacity compensation coefficient
Refrigerant piping one way equivalent length (m)
Gas pipe: ø34.92*
Gas pipe: 38.1
Model FDCH800CKXE6G
(FDCH400 FDCH400CKXE6G)
0
0.80
0.85
0.90
0.95
1.00
20
40
60
80 90100 120 140 160 180
Capacity compensation coefficient
Refrigerant piping one way equivalent length (m)
Gas pipe: 31.8
Gas pipe: 34.92*
Gas pipe: 38.1
Model FDCH735CKXE6G
(FDCH335CKXE6G-K + FDCH400CKXE6G)
Model FDCH680CKXE6G
Model FDCH615CKXE6G
Capacity compensation coefficient
0
20
40
60
80
100 120 140 160 180
Gas pipe: 28.58
0.80
0.85
0.90
0.95
1.00
Refrigerant piping one way equivalent length (m)
Gas pipe: 31.8
90
Capacity compensation coefficient
0
20
40
60
80
100
90
120 140 160 180
Gas pipe: 28.58
0.80
0.85
0.90
0.95
1.00
Refrigerant piping one way equivalent length (m)
Gas pipe: 31.8
(b) Correction of capacity in relation to one way length of refrigerant piping.
(Note) This table is for reference only. If the refrigerant piping one way equivalent after the first branch is extended longer than 40 m, it could
drop further by about 10% in the worst case.
Gas pipe: 25.4
Gas pipe: 28.58
*
0
0.80
0.85
0.90
0.95
1.00
20
40
60
80
100 120 140 160 180
Capacity compensation coefficient
Refrigerant piping one way equivalent length (m)
Model FDCH560CKXE6G
Model FDCH504CKXE6G
Model FDCH450CKXE6G
Model FDCH400CKXE6G
0
0.80
0.85
0.90
0.95
1.00
20
40
60
80
100
90
120 140 160 180
Gas pipe: 28.58
Gas pipe: 31.8
Capacity compensation coefficient
Refrigerant piping one way equivalent length (m)
Capacity compensation coefficient
0
20
40
60
80 90100 120 140 160 180
Gas pipe: 28.58
0.80
0.85
0.90
0.95
1.00
Refrigerant piping one way equivalent length (m)
Gas pipe: 31.8
Gas pipe: 28.58
Gas pipe: 31.8
0
0.80
0.85
0.90
0.95
1.00
20
40
60
80
Refrigerant piping one way equivalent length (m)
Capacity compensation coefficient
100
90
120 140 160 180
Note (1) Parts with the
*
mark show the piping size in case used in Europe.
Summary of Contents for FDCH1010CKXE6G
Page 8: ... 09 KX T 139 2 2 Exterior dimensions Models FDCH335CKXE6G K 400CKXE6G 450CKXE6G PCB003Z141 ...
Page 9: ... 09 KX T 139 Models FDCH504CKXE6G 560CKXE6G 560CKXE6G K 615CKXE6G 680CKXE6G PCB003Z142 ...
Page 10: ... 09 KX T 139 2 3 Electrical wiring Models All model PCB003Z139 ...
Page 41: ......
Page 42: ... 40 09 KX T 139 ...
Page 63: ... 09 KX T 139 Combination use PCB003Z587 61 ...
Page 64: ... 09 KX T 139 2 2 Exterior dimensions Models FDCH335CKXE6G K 400CKXE6G 450CKXE6G PCB003Z589 62 ...
Page 65: ... 09 KX T 139 Models FDCH504CKXE6G 560CKXE6G 560CKXE6G K 615CKXE6G 680CKXE6G PCB003Z590 63 ...
Page 66: ... 09 KX T 139 2 3 Electrical wiring Models All model PCB003Z588 64 ...