110
-
(
φ
20
×
3 pcs.)
(M10
×
4 pcs.)
Unit : mm
A
Minimum allowable space to the obstacles
L1
L2
L3
Air outlet
Air inlet
Air inlet
Maintenance
space
L4
51
40
36
100
845
10
110
50
195
242
279
970
50
15
55
370
40
40
410
20
20
55
60
388
262
38
60
190
580
200
60
15
103
15
50
27
52
110
50
195
Mark
Installation
type
Unit : mm
L2
L3
L4
L1
300
150
5
Open
Open
Open
I
5
300
5
II
150
5
500
III
Liquid piping:
φ
9.52(3/8")
Liquid piping:
φ
9.52(3/8")
Gas piping:
φ
15.88(5/8")
(Flare connecting)
(Flare connecting)
(Flare connecting)
Gas piping:
φ
15.88(5/8")
(Flare connecting)
Terminal block
Opening for
electric wiring
Opening for
piping and
electric wiring
Opening for piping
and electric wiring
Opening for piping
and electric wiring
VIEW A
50
15
70
50
150
40
Opening for
electric wiring
Opening for
piping and
electric wiring
Holes for drain
Holes for anchor bolt
( )
Models FDCVA402HENAR, 502HENAR, 602HENAR
402HESAR,
502HESAR,
602HESAR
Notes
(1) It is prohibited to install in a space enclosed with walls at four
sides.
(2) Unit must be secured with anchor bolts.
Anchor bolt should not protrude more than 15 mm above the
surface.
(3) Where strong winds blow, the blow outlet must be oriented at
right angle against the wind direction.
(4) Secure a space of 1 m or more above the unit.
(5) Barrier standing in front of the blow outlet must be lower than the
height of unit.