200
-
Use the fitting supplied with the unit to connect the drain hose, fastening it at the lowest point so that there is no slack, and
establishing a 10 mm drain slope. * Keep electrical wiring from running beneath the drain hose.
Be sure to fasten the drain hose down with a clamp.
There is danger of water overflowing the drain hose.
WARNING
After piping has been installed, check to make sure water drains well and that there is no overflow.
1) Select the installation location that meets the following conditions and obtain
the customer’s consent.
a) Location where cold and warm air spread all over the room
b) Location where piping and wiring to the outdoors can easily be laid down.
c) Location where the drain can be discharged completely.
d) Location where the wall to mount the unit is rigid.
e) Location where there is no wind obstruction to the air return and air supply
grills.
f) Location not exposed to direct sunshine.
g) Avoid the location exposed to oil splash or vapor.
h) Avoid the location near to the machine emitting high-frequency radio
wave.
i) Avoid the location where the receiver of remote control is subject to strong
illumination.
j) Select the location where the unit can securely be operated by the wireless
remote controller referring to the Article “Effective distance of wireless
remote controller” indicated at the backside.
k) Secure the space for inspection and maintenance work.
(4) Wall mounted type (FDKN)
(a) Selection of installation location
Drain hose
Lowest Point
(
)
Drain hose
Hose Clamp
It can be fastened
from inside or
outside the unit.
10mm
Avoidriding across an elevation
The drain hose
should slope
downward.
Keep free from trape
Do not pipe under water
50 or more
Unit: mm
100 or more
40
or more
(b) Cautions for use of wireless remote controller
1)
Opareting distance of wireless remote controller
Floor
1 m
Wireless remote con-
troller
2 m
Within 5 m
Illumination over suction grill-800 lux.
Receivalle range
60°
Wi
thin
5 m