311
-
Cooling power consumption
Heating power consumption
Cooling running current
Heating running current
Inrush current (L.R.A)
2.02/2.02
2.16/2.16
10.4/10.4
11.1/11.1
(220-240V 50Hz/220V 60Hz)
Item
Model FDCVA302HENAR FDCVA402HENAR FDCVA502HENAR FDCVA602HENAR
kW
A
A
5
2.82/2.82
2.97/2.97
12.3/12.3
13.0/13.0
4.15/4.15
4.19/4.19
18.3/18.3
18.4/18.4
4.64/4.64
4.44/4.44
20.4/20.4
19.5/19.5
Cooling power consumption
Heating power consumption
Cooling running current
Heating running current
Inrush current (L.R.A)
(380-415V 50Hz/380V 60Hz)
Item
Model
FDCVA402HESAR
2.82/2.82
2.97/2.97
4.1/4.3
4.3/4.5
4.15/4.15
4.19/4.19
6.1/6.4
6.1/6.4
5
FDCVA502HESAR
4.64/4.64
4.44/4.44
6.8/7.2
6.5/6.8
FDCVA602HESAR
kW
A
A
(3) Operation
chart
The Multi-Type V series is a system that allows for different models and capacities of indoor units to be connected so the individual
operating characteristics of the indoor and outdoor are provided. Use the procedure shown in Item (c) to calculate the combined
operating characteristics.
(a) Operating characteristic of outdoor unit
Cooling power consumption
Heating power consumption
Cooling running current
Heating running current
Inrush current (L.R.A)
(380-415V 50Hz/380V 60Hz)
Item
Model
FDCVA802HESAR
6.34/6.34
6.20/6.20
9.1/9.1
9.0/9.0
8.71/8.71
7.75/7.75
12.7/12.7
11.4/11.4
FDCVA1002HESAR
kW
A
A
5
Note (1) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
ISO-T1
“UNITARY
AIR-CONDITIONERS”
(b) Operating characteristic of indoor unit
FDTC
Series
(220-240V 50Hz/220V 60Hz)
Notes (1) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
ISO-T1
“UNITARY
AIR-CONDITIONERS”
(2) The values shown in the above table are common to both cooling and heating operations.
Model
Item
FDTCA151R
FDTCA201R
Cooling power consumption
kW
0.046-0.046/0.046
Heating power consumption
0.046-0.046/0.046
Cooling running current
A
0.15-0.14/0.15
Heating running current
0.15-0.14/0.15
Model
Item
FDTA151R
FDTA201R
FDTA251R
FDTA301R
FDTA401R
*
FDTA501R
Cooling power consumption
kW
0.064-0.075/0.079
0.072-0.081/0.090
0.129-0.146
0.150-0.150/0.150
Heating power consumption
0.061-0.071/0.076
0.068-0.078/0.086
0.123-0.140
0.146-0.146/0.146
Cooling running current
A
0.32-0.34/0.42
0.37-0.41/0.42
0.56-0.62
0.48-0.44/0.48
Heating running current
0.30-0.33/0.40
0.36-0.39/0.40
0.54-0.59
0.47-0.43/0.47
FDT
Series
(220-240V 50Hz/220V 60Hz)
* Not available in 60Hz
Model
Item
FDENA151R
FDENA201R
FDENA251R
FDENA301R
FDENA401R
FDENA501R
Cooling power consumption
kW
0.054-0.061/0.061
0.100-0.110/0.110
0.142-0.161/0.166 0.166-0.185/0.200
Heating power consumption
0.050-0.056/0.056
0.091-0.101/0.101
0.130-0.147/0.152 0.152-0.169/0.183
Cooling running current
A
0.25-0.26/0.29
0.46-0.48/0.50
0.65-0.67/0.77
0.77-0.78/0.90
Heating running current
0.23-0.24/0.26
0.42-0.44/0.46
0.59-0.62/0.70
0.70-0.72/0.83
FDEN
Series
(220-240V 50Hz/220V 60Hz)