201
-
Reference hole
WARNING
Level matching mark
450
Unit: mm
Leveling Plates
3) Adjust the level of mounting plate under the condition that four screws are tightened temporarily.
4) Turn the mounting plate around the reference hole to adjust the levelness.
Install the unit where it can bear the weight with sufficient strength margin. In the case of insufficient strength or insufficient
installation work, the unit may fall and cause injury.
(d) Procedure for making hole on the wall
•
Make a downgrade (5°) from the indoors toward the outdoors.
2) Cautions for operation
a)
Orient the remote control switch properly toward the receiver of the unit.
b)
Operating distance is as shown above but it may vary largely depending on the conditions.
c)
Effective distance may be shortened and the receiving may be disturbed when the receiver is under the condition of
direct exposure to sunlight or other strong light like electric bulb, dust is accumulated on it and it is shielded with a
curtain, etc.
(c) Attaching of mounting plate
1) The indoor unit weighs approx, 12kg. Therefore, check whether the portion to install the unit can bear the weight of unit. If
it seems to be danger, reinforce the portion by a plate or a beam before installing the unit. It is not allowed to install the unit
directly on the wall. Whenever you install the unit, use the attached mounting plate.
2) Find structural members (Intermediate pillar, etc.) suitable for mounting the unit, then install the unit firmly while checking
levelness.
Relation between illumination at receiver
unit and operating distance
Caution item for close installation of
multiple units
Piping
Drain hose
(e) Forming of piping and drain hose
1) Rear take out case
a)
Forming of piping
b) Tape
winding
• Hold the root portion of pip-
ing, change the direction then
expand and make forming.
• Wind the tape on the portion which
passes through the hole on the
wall.
• Always make taping on the wiring
which crosses with the piping, if any.
The indoors
Wall
The outdoors
Sealing plate
Sleeve
ø65mm
Wall
Sleeve
Note (1) After forming of piping and before tape winding, confirm that the connecting wire is securely fixed to the terminal block.
3 m
5 m
7
.5 m
60°
720 lu
x
360 lux
180
lux
5 m
5 m
5 m
Receivalle range
Receivalle range
[Condition] Illumination at suction grill face 800 lux
[Top view]
[Top view]
Summary of Contents for FDCVA1002HESAR
Page 107: ... 106 60 17 150 b Wireless remote controller Unit mm ...
Page 119: ... 118 Model FDCVA1002HESAR Polar white ...
Page 133: ......