243
-
CNM3
52X6
52X1
52X2
52X3
52X4
52X8-2
PC3
IC2
C2
X1
CNE
F2
F1
Z2D
Z3D Z4D Z5D
R16
ZD1
CNJ
D2
IC7
TVS1
CNM2
CNW8
CNT
IC9
J8
1 2 3 4
J10
J11
J12
CNR
IC12
CNG
LED2 LED1
CNW9
C13
PC5
C12
C1
L1
C58
IC3
C4
C3
CNY
CNI
CNH
CNN1
SW2
SW10
SW5
1 2 3 4
SW7
J5
J6
J7
J8
SW8
J1
J2
J3
J4
SW9
IC11
IC8
CNB
C11
C41
KN1
CNV
52X7
52X8-1
CNW7
TM1
PC2 PC1
R17
C23
L2
ON
ON
C5
Fan motor
(501, 601)
Power supply PCB
(CNW8)
Connector
(CNT)
Address switch
(SW2)
Heat exchanger thermistor,
Return air thermistor
(Thi-R1, Thi-A)
Heat exchanger
thermistor
(Thi-R2)
J9~J11
(SW10)
DIP switch
(SW5)
J5~J7
(SW8)
DIP switch
(SW9)
J1~J4
(SW7)
Remote
controller
Louver motor
To power supply
(CNW7)
To power supply PCB
(501, 601) (CNW9)
Fan motor
(151~401)
Note (1)
(2)
“Open” means that jumper wire is not provided on the PCB or the
connection is cut.
The replacement PCB is not equipped with jumpers J1 ~ J7. Instead,
SW7 and 8, with the same functions as jumpers J1~J7, are used in the
position where the jumpers were previously. Set SW7 and 8 locally in
accordance with the above table.
Note (1) It is normally ON only in the case of SW9-4.
Slave c
Slave b
Slave a
Master
SW5-2
SW5-1
ON
OFF
ON
OFF
ON
OFF
Setting time : 1000hrs. (Unit stop)
Setting time : 1000hrs. (Display)
Setting time : 600hrs. (Display)
Setting time : 180hrs. (Display factory setting)
SW5-4
SW5-3
ON
OFF
ON
OFF
ON
OFF
Switch
Function
Emergency operation
Normal
Fan control : Powerful mode
Fan control : Mild mode
SW9-3
SW9-4
SW10-1 (J9)
Switch
Function
Auto swing function - Invalid
Auto swing function - Valid
Remote controller air flow –
Remote controller air flow 1 speed
Remote controller air flow 2 speed
Remote controller air flow 3 speed
SW10-3
(J11)
SW10-2
(J10)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
Switch
Function
Input signal for CnT - Level input
Input signal for CnT - Pulse input
Heating thermostat OFF-Lo Fan speed
Heating thermostat OFF-Stop for 5 min then Lo fan speed
Input signal for CnT - Normal operation (Run/Stop)
Input signal for CnT - Operation permission/prohibition
Normal
Set point for Heating offset by +3˚C
Louver free stop control - Invalid
Louver free stop control - Valid
Freeze prevention fan control activated.
Freeze prevention fan control deactivated.
Louver position : Normal
Louver position : For wind 1
J1 (SW7-1)
J2 (SW7-2)
J3 (SW7-3)
J4 (SW7-4)
J5 (SW8-1)
J6 (SW8-2)
J7 (SW8-3)
Closed
Open
(1)
Closed
Open
(1)
Closed
Open
(1)
Closed
Open
(1)
Closed
Open
(1)
Closed
Open
(1)
Closed
Open
(1)
Name
Function
CONTROL SETTING SWITCH (SW5, SW9, SW10)
Function of DIP switch SW5 Master/slave setting and fi lter
sign setting (Usually all turned OFF)
Function of DIP switch SW9
SETTING BY THE JUMPER WIRE
Function of DIP switch SW10
Model: FDT series
Summary of Contents for FDCVA1002HESAR