(5) High static pressure duct type (FDU)
(a) Single
type
Model
FDUVA802HES2R
Model
Item
FDUVA802HES2R
(5)
FDUA801R
FDCVA802HESAR
Nominal cooling capacity
(1)
kW
20.0 [7.0~22.4]
Nominal heating capacity
(1)
kW
22.4 [7.6~25.0]
Power source
3 Phase, 380–415V 50Hz
Operation data
(3)
Cooling power consumption
kW
6.50
Running current (Cooling)
A
10.5
Power factor (Cooling)
%
89
Heating power consumption
kW
6.32
Running current (Heating)
A
10.6
Power factor (Heating)
%
86
Inrush current (L.R.A)
A
5
Noise level
dB(A)
48
57
Exterior dimensions
Height
×
Width
×
Depth
mm
360 × 1570 × 830
1300 × 970 × 370
Net weight
kg
92
122
Refrigerant equipment
Compressor type & Q’ty
–
GT-C5150ND79 × 1
Starting method
–
Direct line start
Heat exchanger
Louver fin & inner grooved tubing
Straight fin & inner grooved tubing
Refrigerant control
–
Electronic expansion valve
Refrigerant
R410A
Quantity
kg
–
5.4 [Pre-charged up to the piping length of 30m]
Refrigerant oil
r
–
1.45 (M-MA32R)
Defrost control
Microcomputer controlled de-icer
Air handling equipment
Fan type & Q’ty
Multiblade centrifugal
×
4
Propeller fan
×
2
Motor
W
200
×
2
120
×
2
Starting method
Direct line start
Direct line start
Air fl ow
CMM
51
Cooling:150, Heating:145
Available static pressure
Pa
Standard:100, Max:200
–
Outside air intake
Available
–
Air filter, Q’ty
Field purchased
–
Shock & vibration absorber
Rubber sleeve (for fan motor)
Rubber mount (for compressor)
Electric heater
W
–
40 (Crank case heater)
Operation control
Operation switch
Wired remote control switch (Optional : RC-E1R)
Wireless kit (Optional : RCND-KIT-HER)
– (Indoor unit side)
Room temperature control
Thermostat by electronics
–
Safety equipment
Internal thermostat for fan motor.
Frost protection thermostat.
Internal thermostat for fan motor.
Anomalous discharge temperature protection.
Installation data
Refrigerant piping size
mm
(in)
Liquid line:
φ
9.52(3/8
″
) Gas line:
φ
25.4(1
″
)
(6)
Connecting method
Brazing piping (Outdoor Liquid piping: Flare)
Drain hose
Connectable with VP25 (I.D. 25mm, O.D. 32mm)
–
Insulation for piping
Necessary (both Liquid & Gas lines)
Accessories
Mounting kit. Drain hose, Reducer kit, (Please see page 218), Accessory pipe (Please see page 220)
Optional parts
–
Notes (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
DB
WB
Cooling
27˚C
19˚C
35˚C
24˚C
ISO-T1
Heating
20˚C
–
7˚C
6˚C
(2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. ISO-T1 “UNITARY AIR-CONDITIONERS”
(3) The operation data indicate when the air-conditioner is operated at 400V 50Hz.
(4) Values in [ ~ ] show the minimum to maximum range.
(5) Not available in 60Hz.
(6) Be sure to use the accessory pipe to connect service valve on the gas side with the fi eld pipe.(Refer to the 220 page).