45
-
Model FDKNA251R
Item
Nominal cooling capacity
(1)
kW
kW
W
CMM
12
dB(A)
mm
298 840 240
Nominal heating capacity
(1)
Power source
Net weight
Refrigerant control
Starting method
Outside air intake
Air filter, Q’ty
Shock & vibration absorber
Room temperature control
Connecting method
Drain hose
Insulation for piping
Accessories
Optional parts
Motor
Air flow(Standard)
Exterior dimensions
Height Width Depth
Refrigerant equipment
Heat exchanger
Internal thermostat for fan motor.
Frost protection thermostat.
Air handling equipment
Fan type & Q’ty
Operation control
Operation switch
Installation data
Refrigerant piping size
Noise level
Model
FDKNA251R
5.6
6.3
1 Phase, 220-240V 50Hz/220V 60Hz
Direct line start
Unavailable
Long life fillter 2 (Washable)
Rubber sleeve (for fan motor)
Flare piping
Connectable with VP16 (I.D.16 mm, O.D.22 mm)
Necessary (both Liquid & Gas lines)
Mounting kit. Drain hose
—
Thermostat by electronics
mm(in)
Safety equipment
Wireless remote control switch (Optional: RCN-E1R)
Wired remote control switch (Optioanl: RC-E1R)
Powerful mode Hi: 48 Me: 45 Lo: 42
Mild mode Hi: 45 Me: 42 Lo: 39
Powerful mode Hi: 14 Me: 13 Lo: 11
Mild mode Hi: 13 Me: 11 Lo: 10
Slitted fin & inner grooved tubing
33 1
Tangential fan 1
Liquid line: 6.35 (1/4")
Gas line: 15.88 (5/8")
(1) The data are measured at the following conditions.
Notes
(2) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
ISO-T1 "UNITARY AIR-CONDITIONERS"
Item
Indoor air temperature
Outdoor air temperature
Standards
ISO-T1
Operation
DB
WB
DB
WB
Cooling
27
Heating
20
19
35
7
24
6
kg