'16 • PAC-T-240
(6) Wall mounted type (SRK)
Model
Item
SRK100VNP1ZR
Indoor unit
SRK100ZR-S
Outdoor unit
FDC100VNP
Power source
1 Phase 220-240V 50Hz / 220V 60Hz
Operation
data
Nominal cooling capacity (range)
kW
10.0 [ 2.4(Min.)— 10.5(Max.)]
Nominal heating capacity (range)
kW
11.2 [ 3.2(Min.)— 11.5(Max.)]
Heating capacity (H2)
kW
—
Power consumption
Cooling
kW
3.09 ( 0.6 - 3.2 )
Heating
3.28 ( 0.6 - 3.6 )
Heating (H2)
—
Max power consumption
4.6
Running current
Cooling
A
14.2 / 13.6 / 13.0 (220/ 230/ 240 V)
Heating
15.1 / 14.4 / 13.8 (220/ 230/ 240 V)
Inrush current, max current
15.1 / 14.4 / 13.8 (220/ 230/ 240 V) Max. 21
Power factor
Cooling
%
99
Heating
99
EER
Cooling
3.24
COP
Heating
3.41
Heating (H2)
—
Sound power level
Cooling
dB(A)
63
70
Heating
63
74
Sound pressure level
Cooling
Hi : 48 Me : 45 Lo : 40 ULo : 27
57
Heating
Hi : 48 Me : 43 Lo : 38 ULo : 30
61
Silent mode sound pressure level
—
Cooling:50 / Heating:49
Exterior dimensions (Height × Width × Depth)
mm
339 x 1197 x 262
845×970×370
Exterior appearance
( Munsell color )
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
(
4.2Y7.5/1.1
)
near equivalent
Net weight
kg
16.5
70
Compressor type & Q'ty
—
RMT5126MCE1 ( Twin rotary type )×1
Compressor motor (Starting method)
kW
—
4.0 ( Inverter driven )
Refrigerant oil (Amount, type)
—
0.90 ( DIAMOND FREEZE MA68 )
Refrigerant (Type, amount, pre-charge length)
kg
R410A 2.55 in outdoor unit (incl. the amount for the piping of 15m)
Heat exchanger
Louver fin & inner grooved tubing
M fin & inner grooved tubing
Refrigerant control
Capillary tubes + Electronic expansion valve
Fan type & Q'ty
Tangential fan x 1
Propeller fan ×1
Fan motor (Starting method)
W
56 x1 (Direct drive)
86 x1 (Direct drive)
Air flow
Cooling
m
3
/min
Hi : 24.5 Me : 21.3 Lo : 17.6 ULo : 10.4
75
Heating
Hi : 27.5 Me: 23.2 Lo : 19.1 ULo : 13.6
80
Available external static pressure
Pa
0
0
Outside air intake
Not possible
—
Air filter, Quality / Quantity
Polypropylene net ( washable ) x 2
—
Shock & vibration absorber
Rubber sleeve(for fan motor)
Rubber sleeve (for fan motor & compressor)
Electric heater
—
—
Operation
control
Remote control
Wireless-Remote control
Room temperature control
Microcomputer thermostat
Operation display
RUN: Green, TIMER: Yellow, HI POWER: Green, 3D AUTO: Green
Safety equipments
Compressor overheat protection, Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection( High pressure control ), Cooling overload protection
Installation
data
Refrigerant piping size ( O.D. )
mm
Liquid line:
φ
9.52 (3/8") Gas line:
φ
15.88 (5/8")
Connecting method
Flare connection
Flare connection
Attached length of piping
m
Liquid line : 0.78 / Gas line : 0.72
—
Insulation for piping
Necessary ( Both sides ), independent
Refrigerant line (one way) length
m
Max.30m
Vertical height diff. between O.U. and I.U.
m
Max.20 ( Outdoor unit is higher ) / Max.20 ( Outdoor unit is lower )
Drain hose
Hose connectable ( VP 16 )
Holes
φ
20 × 3pcs
Drain pump, max lift height
mm
—
—
Recommended breaker size
A
30
L.R.A. (Locked rotor ampere)
A
5 / 5 / 5 (220/ 230/ 240 V)
Interconnecting wires Size × Core number
1.5mm
2
x 4 cores ( Including earth cable ) / Terminal block ( Screw fixing type )
IP number
IPX0
IPX4
Standard accessories
Mounting kit, Clean filter ( Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1 )
Option parts
Interface kit ( SC-BIKN-E ), Drain Hose
Note (1) The data are measured at the following conditions.
The pipe length is 5m.
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat
higher due to ambient conditions.
(4) Select the breaker size according to the own national standard.
Item
Operation
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
DB
WB
Cooling
27˚C
19˚C
35˚C
24˚C
ISO5151-T1
Heating
20˚C
—
7˚C
6˚C
ISO5151-H1
Heating (H2)
20˚C
—
2˚C
1˚C
ISO5151-H2
D
RWA000Z262