131
-
'16 • PAC-T-240
'09•SRK-DB-087D
(8)
ޓ
Flap and louver control
(a) Flap
(b) Louver
(c) Swing
1)
2)
(c) Memory flap (Flap or Louver stopped)
(d) When not operating
COOL , DRY, FAN
Remote control
display
HEAT
Approx. 5°
Approx. 20°
Approx. 20°
Approx. 35°
Approx. 35°
Approx. 45°
Approx. 70°
Approx. 50°
Approx. 60°
Approx. 70°
Angle of Flap from Horizontal
Center installation
Remote control
display
Angle of louver
Left approx. 50° Left approx. 20°
Center
Right approx. 20° Right approx. 50°
In HEAT operation
In COOL, DRY, FAN operation
Approx. 35°
Approx. 80°
Approx.
5°
Approx. 60°
U/D
U/D
L/R
L/R
(Swing)
(Flap stopped)
(Louver stopped)
(Swing)
(7) Economy operation
Pressing the HI POWER/ECONO button initiate a soft operation with the power suppressed in order to avoid an excessive cooling
or heating. The unit operate 1.0
℃
higher than the setting temperature during cooling or 2.0
℃
lower than that during heating. The
remote control displays ECONO mark and the FAN SPEED display disappears.
(a) It will go into ECONOMY operation at the next time the air conditioner runs in the following cases.
①
When the air-conditioner is stopped by ON/OFF button during ECONOMY operation.
②
When the air-conditioner is stopped in SLEEP or OFF TIMER operation during ECONOMY operation.
③
When the operation is retrieved from CLEAN or ALLERGEN CLEAR operation.
(b) When the following operation are set, ECONOMY operation will be canceled.
①
When the HI POWER/ECONO button is pressed again.
②
When the operation mode is changed DRY to FAN.
(c) Not operable while the air-conditioner is OFF.
(d) The setting temperature is adjusted according to the following table.
①
at the start of operation.
②
one hour after the start of operation.
③
two hours after the start of operation.
Temperature
adjustment
Cooling
Heating
①+0.5
①-1.0
②+1.0
②-2.0
③
③
Mode
Item
+0.5
0
-0.5
60
50
40
・
Cooling
Humidity (%)
+0.5
0
-0.5
55
50
45
・
Heating
Humidity (%)