68
-
'16 • PAC-T-240
①
Before installation
②
Selection of installation place for the indoor unit
This manual is for the installation of an indoor unit.
For electrical wiring work (Indoor), refer to the page 80. For remote control installation, refer to the
page 84. For wireless kit installation, refer to the page 223. For electrical wiring work (Outdoor) and
refrigerant pipe work installation for outdoor unit, refer to the page 98.
SAFETY PRECAUTIONS
WARNING
CAUTION
t4FDVSFTVGmDJFOUTQBDFTGPSJOTQFDUJPOBOENBJOUFOBODF
ATTENTION:
Model and po
XFSTVQQMZTQFDJmD
ation
Check.
(1)
For heat insulation of flare nut
1
Pipe cover
1 pc For gas side
For liquid side
2
Pipe cover
1 pc
3
Strap
4 pcs
(2)
For installation
1
Fall-prevention fitting
Wood screw
Washer
Rubber bushing
L fitting
*3
For No. 1
For No. 2 wood screw
For refrigerant and drain pipes
*4
2
1 pc
2 pcs
2 pcs
1 pc
2 pcs
3
4
5
*3
*4
*1
、
2
Note) Nos. 1 and 5 are used also as hardware for packing.
Space for installation and service
WARNING
Service
space
600
600
1000
100
50
Air outlet
Air inlet
(Unite: mm)
50
Where the accessories are put in
*1
Pipes, wires and small parts
Accessory
*1. Open the air inlet grill and Nos. (1) will be found in the unit.
*2. Nos. (2)-2-4 will be found at the same place as 1.
*3. F
BMMQSFWFOUJPOmUUJOHJTNPVOUJOHPOUIFUPQQBOFMPGUIFVOJU
*4.
-mUUJOHTBSFNPVOUFEPOUIFCPUUPNQBSUPGUIFVOJU
t
Install the unit securely on a floor that can endure its weight
TVGmDJFOUMZ *OTVGm
-
cient strength or incorrect installation could result in injuries if the unit falls.
4FMFDU
a place for installation where the following conditions are
GVMmMMFE
with customer's consent.
t8IFSFDPPMPSIPUBJSDBOCFCMPXOTVGmDJFOUMZBOEXJEFMZ
t8IFSFUIFQJQJOHBOEXJSJOHXPSLUPPVUEPPSVOJUDBOCFEPOF
easily.
t8IFSFESBJOBHFXBUFSDBOSVOPGGDPNQMFUFMZ
t8IFSFUIFJOTUBMMBUJPOnPPSJTTUSPOHFOPVHI
t8IFSFUIFVOJUJUTQSPUFDUFEGSPNEJSFDUFYQPTVSFUPTVOMJHIU
.
t8IFSFUIFSFJTOPPCTUBDMFBUIFBJSJOMFUBOEBJSPVUMFU
t8IFSFUIFmSFBMBSNBQQBSBUVTXJMMOPUCFBDUJWBUFECZNBMGVO
ction.
8IFSF5IFSFJTOPSJTLGPSTIPSUDJSDVJUPGBJS
①
4FMFDUUIFTVJUBCMFBSFBTUPJOTUBMMUIFVOJUVOEFS
approval of the user.
・
Areas where the indoor unit can deliver hot and cold wind su
GmDJFOUM
y.
4VH
gest to the user to use a circulator
if the ceiling height is over 3m to avoid warm air being accumulated on the ceiling.
・
Areas where there is enough space to install and service.
・
Areas where it can be drained properly. Areas where drain pipe descending slope can be taken.
・
Areas where there is no obstruction of airflow on both air return grille and air supply port.
・
"SFBTXIFSFmSFBMBSNXJMMOPUCFBDDJEFOUBMMZBDUJW
ated by the air-conditioner.
・
Areas where the supply air does not short-circuit.
・
Areas where it is not influenced by draft air.
・
"SFBTOPUFYQPTFEUPEJSFDUTVOMJHIU
・
Areas where dew point is lower than around 23°C and relative humidity is lower than 80%.
This indoor unit is tested under the condition of JI
4
(Japan Industrial
4
tandard) high humidity condition
and con
m
rmed there is no problem. However, there is some risk of condensation drop if the air-
conditioner is operated under the severer condition than mentioned above.
If there is a possibility to use it under such a condition, attach additional insulation of 10 to 20mm
thick for entire surface of indoor unit, refrigeration pipe and drain pipe.
・
Areas where TV and radio stays away more than 1m. (It could cause jamming and noise.)
・
Areas where any items which will be damaged by getting wet are not placed such as food, table wares,
server, or medical equipment under the unit.
・
Areas where there is no influence by the heat which cookware generates.
・
"SFBTXIFSFOPUFYQPTFEUPPJMNJTU
, powder and/or steam directly such as above fryer.
・
Areas where lighting device such as fluorescent light or incandescent light doesn’t affect the operation.
(A beam from lighting device sometimes affects the infrared receiver for the wireless remote control and
the air-conditioner might not work properly.)
・
8IFO
operating the suction air processing unit independently, it operates in the outdoor air processing
mode.
Blowout temperatures are not same at the standard unit operation and the outdoor air processing mode
operations.
4JODF
the temperatures become higher during cooling or lower during heating, take care of the direction
of blowout outlet.
Avoid directing the blowout outlet to the space where people are present.
②
Check if the place where the air conditioner is installed can hold the weight of the unit. If it is not able to
hold, reinforce the structure with boards and beams strong enough to hold it. If the strength is not
enough, it could cause injury due to unit falling.
●
Read the
i4"'&5:13&$"65*0/4
”
DBSFGVMMZmSTUPGBMMBOEUIFOTUSJDUMZGPMM
ow it during the installation work
in order to protect yourself.
●
The precautionary items mentioned below are distinguished into two levels, and .
:
8SPOHJOTUBMM
ation would cause serious consequences such as injuries or death.
:
8SPOHJOTUBMM
ation might cause serious consequences depending on circumstances.
Both mentions the important items to protect your health and safety so strictly follow them by any means.
●
The meanings of “Marks” used here are as shown on the right:
●
After completing the installation,
EPDPNNJTTJPOJOHUPDPOmSNUIFSFBSFOPBCOPSNBMJUJFT
,
BOEFYQMBJOUPUIF
customers about
i4"'&5:13&$"65*0/4w
, correct opera
UJPONFUIPEBOENBJOUFOBODFNFUIPE BJSmMUFS
cleaning, operation method and temperature setting method) with user’s manual of this unit.
Ask your customers to keep this installation manual together with the user’s manual. Also, ask them to hand
over the user’s manual to the new user when the owner is changed.
$"65*0/
Never do it under any circumstances.
$"65*0/
●
Installation should be performed by the specialist.
If you install the unit by yourself, it may lead to serious trouble such as water leakage, electric shock,
mSF
, and injury due to overturn
of the unit.
●
Install the system correctly according to these installation manuals.
Improper installa
UJPONBZDBVTFFYQMPTJPO
, injury, water leakage, electric shock,
BOEmSF
●
Check
the
density
refered
by
the
foumula (accordance
with
ISO5149).
If
the
density
FYDFFET
the
limit
density, please
consult
the dealer and
installate
the
ventilation
system.
●
Use the genuine accessories and the specified parts for installation.
*GQBSUTVOTQFDJmFECZPVSDPNQB
ny are used it could cause water leakage, electric shock,
mSF
, and injury due to overturn of the unit.
●
Ventilate the working area well in case the refrigerant leaks during installation.
*GUIFSFGSJHFSBOUDPOUBDUTUIFmSF
,
UPYJDHBTJTQSPEVDFE
●
Install the unit in a location that can hold heavy weight.
Improper installation may cause the unit to fall leading to accidents.
●
Install the unit properly in order to be able to withstand strong winds such as typhoons, and earthquakes.
Improper installation may cause the unit to fall leading to accidents.
●
Do not mix air in to the cooling cycle on installation or removal of the air-conditioner.
*GBJSJTNJYFEJO
, the pressure in the cooling cyc
MFXJMMSJTFBCOPSNBMMZBOENBZDBVTFFYQMPTJPOBOEJOKVSJFT
●
Be sure to have the electrical wiring work done by qualified electrical installer, and use exclusive circuit.
Po
XFSTPVSDFXJUIJOTVGmDJFOUD
a
QBDJUZBOEJNQSPQFSXPSLDBODBVTFFMFDUSJDTIPDLBOEmSF
●
Use specified wire for electrical wiring, fasten the wiring to the terminal securely, and hold the cable securely in
order not to apply unexpected stress on the terminal.
Loose connections or hold could result in abnormal heat genera
UJPOPSmSF
●
Arrange the electrical wires in the control box properly to prevent them from rising. Fit the lid of the services
panel property.
*NQSPQFSmUUJOHNBZDBVTFBCOPSNBMIF
a
UBOEmSF
●
Check for refrigerant gas leakage after installation is completed.
If the refrigerant gas leaks into the house and comes in contact with a fan heater, a stove, or an oven,
UPYJDHBTJTQSPEVDFE
●
Use the specified pipe, flare nut, and tools for R410A.
6TJOHFYJTUJOHQBSUT 3DPVMEDBVTFUIFVOJUGBJMVSFBOETFSJPVTBDDJEFOUEVFUPFYQMPTJPOPGUIFDPPMJOH
cycle.
●
Tighten the flare nut according to the specified method by with torque wrench.
*GUIFnBSFOVUXFSFUJHIUFOFEXJUIFYDFTTUPSRVF
, it could cause burst and refrigerant leakage after a long period.
●
Do not put the drainage pipe directly into drainage channels where poisonous gases such as sulfide gas can
occur.
Poisonous gases will flow into the room through drainage pipe and seriously affect the user's health and safety. This can also
cause the corrosion of the indoor unit and a resultant unit failure or refrigerant leak.
●
Connect the pipes for refrigeration circuit securely in installation work before compressor is operated.
If the compressor is operated when the service valve is open without connecting the pipe,
JUDPVMEDBVTFFYQMPTJPOBOEJOKVSJFTEVF
to abnormal high pressure in the system.
●
Stop the compressor before removing the pipe after shutting the service valve on pump down work.
If the pipe is removed when the compressor is in operation with the service valve open,
BJSXPVMECFNJYFEJOUIFSFGSJHFS
ation circuit
BOEJUDPVMEDBVTFFYQMPTJPOBOEJOKVSJFTEVFUPBCOPSNBMIJHI
pressure in the cooling cycle.
●
Only use prescribed option parts. The installation must be carried out by the qualified installer.
If you install the system by yourself, it can cause serious trouble such as water leaks, electric shocks,
mSF
●
Do not repair by yourself. And consult with the dealer about repair.
Improper repair may cause water leakage,
FMFDUSJDTIPDLPSmSF
●
Consult the dealer or a specialist about removal of the air-conditioner.
Improper installation may cause water leakage,
FMFDUSJDTIPDLPSmSF
●
Turn off the power source during servicing or inspection work.
If the power is supplied during servicing or inspection work, it could cause electric shock and injury by the operating fan.
●
Do not run the unit when the panel or protection guard are taken off.
Touching the rotating equipment, hot surface, or high voltage section could cause an injury to be caught in the machine, to get
burned, or electric shock.
●
Shut off the power before electrical wiring work.
It could cause electric shock, unit failure and improper running.
●
Perform earth wiring surely.
Do not connect the earth wiring to the gas pipe, water pipe, lightning rod and telephone earth wiring. Imperfect earth work
HSPVOEJOHDPVMEDBVTFBOFMFDUSJDTIPDLPSmSFJGTPNFUSPVCM
e or earth leakage occurs.
●
Earth leakage breaker must be installed.
6OMFTTUIFFBSUIMFBL
age circuit breaker is provided,
JGDPVMEDBVTFBmSFPSFMFDUSJDTIPDL
●
Use the circuit breaker of correct capacity. Circuit breaker should be the one that disconnect all
poles under over current.
6TJOHUIFJODPSSFDUPOFDPVMEDBVTFUIFTZTUFNGBJMVSFBOEmSF
●
Do not use any materials other than a fuse of correct capacity where a fuse should be used.
$POOFDUJOHUIFDJSDVJUCZXJSFPSDPQQFSXJSFDPVMEDBVTFVOJUGBJMVSFBOEmSF
●
Do not install the indoor unit near the location where there is possibility of flammable gas leakages.
If the gas leaks and gathers around the unit,
JUDPVMEDBVTFmSF
●
Do not install and use the unit where corrosive gas (such as sulfurous acid gas etc.) or flammable gas (such
as thinner, petroleum etc.) may be generated or accumulated, or volatile flammable substances are handled.
It could cause the corrosion of hea
UFYDIBOHF
r, breakage of plastic parts etc.
"OEJOnBNNBCMFHBTDPVMEDBVTFmSF
●
Secure a space for installation, inspection and maintenance specified in the manual.
*OTVGmDJFOUTQBDFDBOSFTVMUJOBDDJEFOUTVDIBTQFSTPOBMJOKV
ry due to falling from the installation place.
●
Do not use the indoor unit at the place where water splashes such as laundry.
Indoor unit is not waterproof.
*UDPVMEDBVTFFMFDUSJDTIPDLBOEmSF
●
Do not use the indoor unit for a special purpose such as food storage, cooling for precision
instrument, preservation of animals, plants, and a work of art.
It could cause the damage of the items.
●
Do not install nor use the system near equipments which generate electromagnetic wave or high harmonics.
&RVJQNFOUTMJLFJOWFSUFSFRVJQNFOU
, private power generator, high-frequency medical equipment, or telecommunication
equipment might influence the air-conditioner and cause a malfunction and breakdown. Or the air-conditioner might
influence medical equipments or telecommunication equipments, and obstruct their medical activity or cause jamming.
●
Do not install the remote control at the direct sunlight.
It could cause breakdown or deformation of the remote control.
●
Do not install the indoor unit at the place listed below.
· Places where flammable gas could leak.
·
1MBDFTXIFSFDBSCPOmCF
r, metal powder or any powder is floated.
· Place where the substances which affect the air-conditioner are generated
TVDIBTTVMmEFHBT
, chloride gas, acid, alkali or ammonic atmospheres.
·
1MBDFTFYQPTFEUPPJMNJTUPSTUFBNEJSFDUM
y.
· On vehicles and ships
· Places where machinery which generates high harmonics is used.
●
Do not install the indoor unit in the locations listed below (Be sure to install the indoor unit
according to the installation manual for each model because each indoor unit has each limitation)
· Locations with any obstacles which can prevent inlet and outlet air of the unit
· Locations where vibra
UJPODBOCFBNQMJmFEEVFUPJOTVGmDJFOUTUSFOHUIPGTUSVDUVSF
· Loca
UJPOTXIFSFUIFJOGSBSFESFDFJWFSJTFYQPTFEUPUIFEJSFDUTVOMJHIUPSUIFTUSPOHMJHIUCFBN
. (in case of the
JOGSBSFETQFDJmD
ation unit)
· Locations where an equipment affected by high harmonics is placed. (TV set or radio receiver is placed within 5m)
· Locations where drainage cannot run off safely.
It can affect performance or function and etc..
●
Do not put any valuables which will break down by getting wet under the air-conditioner.
Condensation could drop when the relative humidity is higher than 80% or drain pipe is clogged, and it damages user’s belongings.
●
Do not use the base frame for the outdoor unit which is corroded or damaged after a long period of use.
It could cause the unit falling down and injury.
●
Pay attention not to damage the drain pan by weld sputter when brazing work is done near the unit.
If sputter entered into the unit during brazing work, it could cause damage (pinhole) of drain pan and leakage of water.
To avoid damaging, keep the indoor unit packed or cover the indoor unit.
●
Install the drain pipe to drain the water surely according to the installation manual.
Improper connection of the drain pipe may cause dropping water into room and damaging user’s belongings.
●
Do not share the drain pipe for indoor unit and GHP (Gas Heat Pump system) outdoor unit.
T
PYJDFYIBVTUHBTXPVMEn
ow into room and it might cause serious dama
HF TPNFQPJTPOJOHPSEFmDJFO
c
ZPGPYZHFOUP
user’s health and safety.
●
Be sure to perform air tightness test by pressurizing with nitrogen gas after completed refrigerant piping work.
*GUIFEFOTJUZPGSFGSJHFSBOUFYDFFETUIFMJNJUJOUIFFWFOUPGSFGSJHFSBOUMFBL
age in the small room,
MBDLPGPYZHFODBO
occur, which can cause serious accidents.
●
For drain pipe installation, be sure to make descending slope of greater than 1/100, not to make traps,
and not to make air-bleeding.
Check if the drainage is correctly done during commissioning and ensure the space for inspection and maintenance.
●
Ensure the insulation on the pipes for refrigeration circuit so as not to condense water.
Incomplete insulation could cause condensation and it would wet ceiling, floor, and any other valuables.
●
Do not install the outdoor unit where is likely to be a nest for insects and small animals.
Insects and small animals could come into the electronic components and cause breakdo
XOBOEmSF
. Instruct the user to
keep the surroundings clean.
●
Pay extra attention, carrying the unit by hand.
Carry the unit with 2 people if it is heavier than 20kg. Do not use the plastic straps but the grabbing place, moving the unit
by hand.
6TFQSPUFDUJWFHMPWFTJOPSEFSUP
avoid injur
ZCZUIFBMVNJOVNmO
●
Make sure to dispose of the packaging material.
Leaving the materials may cause injury as metals like nail and woods are used in the package.
●
Do not operate the system without the air filter.
It may cause the breakdown of the system due to clogging of the hea
UFYDIBOHF
r.
●
Do not touch any button with wet hands.
It could cause electric shock.
●
Do not touch the refrigerant piping with bare hands when in operation.
The pipe during operation would become very hot or cold according to the operating condition, and it could cause a burn or frostbite.
●
Do not clean up the air-conditioner with water.
It could cause electric shock.
●
Do not turn off the power source immediately after stopping the operation.
Be sure to wait for more than 5 minutes. Otherwise it could cause water leakage or breakdown.
●
Do not control the operation with the circuit breaker.
*UDPVMEDBVTFmSFPSX
ater leakage. In addition, the fan may start opera
UJPOVOFYQFDUFEMZBOEJUNBZDBVTFJOKV
ry.
Always do it according to the instruction.
· Places where cosmetics or special sprays are
frequently used.
· Highly salted area such as beach.
· Heavy snow area
· Places where the system is affected by
smoke from a chimney.
· Altitude over 1000m
○
Install the unit properly
according to this
instruction manual.
○
Is it in accordance with
the construction plan?
PGA012D404A
A
③
Carrying-in and installation of the unit
①
Loosen screws (2 pcs) and remove the
GBMMQSFWFOUJPOmUUJOH
②
4FMFDU
a position to
mY
the fall-prevention
mUUJOH
as illustrated and
mY
it to the top of unit and the
wall.
・
The
mYJOH
positon of the fall-prevention
mUUJOH
is as illastrated below.
ATTENTION:
t#FTVSFUPmYUIFVOJUXJUI-mUUJOHTBOEUIFGBMMQSFWFOUJPOmUUJOH
Fitting facing upward
Fitting facing downward
1815〜1840
25〜50
25〜50
1860〜1885
Round head wood screw
Tapping screw
Procedure for preventing the unit from falling
Fall-prevention fitting
Top panel
L fitting
(1) F
JYJOHUIFVOJUXJUIUIFGBMMQSFWFOUJPOmUUJOH
Fixing position (Fall-prevention fitting)
・
Since the unit is tall, secure the unit no sooner than setting it in place.
Screw
Fall-prevention
fitting
For fixing to the wall
For securing the unit
t%JNFOTJPOTJOEJDBUFUIFBMMPXBODFGPSBEKVTUNFOUCFUXFFOUIF
unit and the wall or floor.
t'JYUIFMPOHFSTJEFPGmUUJOHUPUIFVOJU
t8IFOUIFmUUJOHJTGBDFEEPXOXBSEmYJUUPUIFXBMMmSTU
ATTENTION:
Carrying-in
Carry with the front face at top.
t
Carry in the unit kept in a package as near as possible to the installa-
tion place.
t8IFO
it is necessary to unpack the unit before carrying in,
TVGmDJFOU
care must be taken not to damage it by using nylon slings or the like.
Note) Do not hold on the air inlet grill, air outlet louver or other
sections made of plastics.
t 8IFO
placing the unit on the floor after unpacking, be sure to have
its front face at the top.
(Unit front)
128
128
140
140
Mount the fall-prevention fitting at right or left position.