69
–
'17 • KX-T-254
-
133
-
'16 • PAC-T-251
(37) Peak-cut timer (RC-EX3 only)
Power consumption can be reduced by restricting the maximum capacity.
Set the [Start time], the [End time] and the capacity limit % (Peak-cut %).
・
4-operation patterns per day can be set at maximum.
・
The setting time can be changed by 5-minutes interval.
・
The selectable range of capacity limit % (Peak-cut %) is from 0% to 40-80% (20% interval)
.
・
Holiday setting is available.
(33) Motion sensor control (RC-EX3 only)
The sensor determines the presence of people and the amount of activity, and the following controls are done by the motion
sensor. Following settings are necessary to activate motion sensor control.
(a) Infrared (motion) sensor setting : Installation setting of remote control.
The indoor unit which is set to "Enable" become valid.
(b) Infrared (motion) sensor control : Energy-saving setting of remote control.
The function which is set to "Enable" become valid.
(i) Power saving control
The set temperature is adjusted according to the presence of people and their amount of activity detected by the infrared
sensor.
(ii) Auto-off control
When no activity is deteced for 1 hour, unit will go stand-by mode. Unit will re-start operation automatically by activity
detection during the stand-by mode.
(38) Motion sensor control (RC-EX3 only)
The sensor determines the presence of people and the amount of activity, and the following controls are done by the motion sensor.
Following settings are necessary to activate motion sensor control.
(a) Infrared (motion) sensor setting: Installation setting of remote control
The indoor unit which is set to “Enable” become valid.
(b) Infrared (motion) sensor control: Energy-saving setting of remote control
The function which is set to “Enable” become valid.
(i)
Power saving control
The set temperature is adjusted according to the presence of people and their amount of activity detected by the
infrared sensor.
(ii)
Auto-off control
When no activity is detected for 1 hour, unit will go stand-by mode. Unit will re-start operation automatically by
activity detection during the stand-by mode.