0
-
'14 • KX-T
-222
3.2 Outdoor air pr
ocessing unit (FDU-F)
Model FDU650FKXZE1
Power PCB
WH
8
9
10
11
12
8
9
10
11
12
CNW2
WH
CNW1
WH
L
N
WH
RD
YE/GN
3
5
CNW0
WH
1
TB1
Power circuit
WH
WH
WH
WH
WH
WH
WH
WH
WH
WH
WH
WH
3
4
5
6
7
1
2
5
6
7
2
3
4
1
F1(5A)
YE/GN
Color
Mark
BK
Color Marks
Black
BL
Blue
RD
Red
WH
White
YE
Yellow
YE/GN Yellow/Green
RD
WH
control of heat recovery
Connector for branching
3-pipe systems
CNU
BL
Power source
220ー240V 50Hz
Single-phase
Power source
220V 60Hz
between indoor units
Power source line
Earth
line
RD
RD
1
2
CNI
BL
CNR
WH
FS
CNZ
CND
For HA
WH
BK
1
2
CNTA
BL
RD
t°
Control PCB
RD
YE
t°
YE
BK
t°
BK
1
2
3
4
5
6
BK
t°
BK
1
2
XR1
XR2
XR3
XR4
XR5(Remote operation
1
2
3
4
5
6
+12
SW2
SW6
SW5
SW7
LED・2 LED・3
X
Y
1
3
X
Y
t°
TB2
WH
BK
CNB
WH
CNN
YE
CNH
BK
CNT
BL
M
1 4 5 6 7
RD
F4
(2A)
CNM2
BK
(Operation)
(Heating)
(Thermo ON)
(Inspection)
Th
C
Th
-R1
Th
-R2
Th -R3
Th
-A
Remote control
FM2
I
I
I
I
input:volt-free contact)
1
2
3
4
5
6
CNA
RD
SM
WH
YE
OR
BL
RD
M
SW1
SW3 SW4
CNK2
Superlink(spare)
JSL1
BK
A
B
1
2
(Shielded cord)
Signal line
between indoor units
Signal line
CNK1
WH
BL
RD
DM
M
RD
WH
For heat recovery 3-pipe systems
(20S)
(SVH)
(SVG)
(SVE)
XB1
XB2
XB3
XB4
1
2
3
4
5
CNT2
RD
+12
Notes 1. indicates wiring on site.
2. Use twin core shielded cord(0.75〜1.25mm
2
)at signal line between indoor unit
and outdoor unit, and signal line between indoor units.
3. Use twin core cord(0.3mm
2
) at remote control line. See spec sheet
of remote control in case that the total length is more than 100m.
4. Do not put signal line and remote control line alongside power source line.
BK WH
BL
+12
1
2
CNWR
WH
L
YE
FS
FM2
SW2
Connector
CNA-Z
Drain motor
DM
TB1
SW6
Operation check, Drain motor test run
SW7-1
Fuse
F1,4
Th -R1,2,3
Th -A
Thc
LED・3
LED・2
TB2
Float switch
Indication lamp(Green-Normal operation)
Indication lamp(Red-Inspection)
Indoor unit address:ones place
Model capacity setting
Terminal block (Power source)(□mark)
Terminal block (Signal line)(□mark)
Thermistor (Remote control)
I
I
Thermistor (Return air)
Thermistor (Heat exchanger)
version of Superlink protocol
Fan motor
JSL1
Live Superlink terminal setting(For spare)
SM
Stepping motor (For electronic expansion valve)
SW1
Indoor unit address:tens place
SW4
Outdoor unit address:ones place
SW3
Outdoor unit address:tens place
SW5-1
Automatic adjustment/Fixed previous
SW5-2
Indoor unit address:hundreds place
L
Reactor
(Remote operation input:
volt-free contact)
Powerful mode Valid/Invalid
SW7-3
Prepare on site
OR
Orange
Meaning of marks
Parts name
Mark
P
JG
0
0
0
Z
2
9
8