9
−
Push the Run/Stop switch.
Operation lamp (green) lights and operation starts.
When the operation stops, all operation buttons on the screen turn off.
When the set lighting time of backlight (
☞
page41) is counted up, the
backlight turns off.
When the screen is tapped, the backlight lights, and all operation buttons
are displayed.
2. Menu items
Note
・
Do not shut down the power supply immediately after the stop of operation.
It should be waited for more than 5 minutes till the residual operation time of drain motor
is counted up. Otherwise, it could cause water leakage or breakdown.
・
A message “Invalid request” may be displayed when a button is pushed. This is not a fault but it is because the button operation is set to
the “Disable”. (
☞
page 60)
・
The unit starts to operate initially with the following settings after the power on. These settings can be changed as desired.
Central
control
……
OFF
Operation
mode
……
With auto mode: Auto cooling
……
Without auto mode: Cooling
Set
temp
……
23.0°C
Fan
speed
……
3-speed
Flap
direction
……
When cooling: position 2, when heating: position 3 (
☞
page 11)
*
:KHQDQ)'.ZLWKDOHIWULJKWÀDSLVFRQQHFWHGOHIWULJKWÀDSGLUHFWLRQFHQWHU'$872GLVDEOHG
・
In the following cases, a message “Operation mode is invalid.” is displayed and it changes to the fan operation, because operation
modes are not matched.
①
When Heating (including auto heating) is selected for Operation mode while using an OU for cooling only.
②
When Heating is selected for Operation mode while controlling multiple units including units allowed for both cooling and heating and units
for cooling only.
③
When different operation modes are selected between IUs which are connected to a OU that do not allow mixed operation of cooling
and heating.
Advice
Press the Run/Stop switch while the unit is in operation.
The operation lamp turns off and the operation stops.
Stop
Run