−
62
−
■
Setting temp range
Limited range of setting temperature in the heating or the cooling operation can be selected.
3
Set the start time for the Outdoor unit silent mode timer.
Select a desired time (at 5-min intervals) with the
▲
▼
buttons.
If the Set button is tapped after setting the start time, the display
changes to the end time setting screen. Set a desired time (at 5-min
intervals) for the end time and tap the Set button.
1
Tap the Menu button on the TOP screen and select User setting
⇒
Administrator settings
⇒
Setting temp range .
2
Setting temp range menu screen is displayed.
①
Setting upper/lower limit temp in cooling (
☞
2
)
... Set the range of setting temperature in the cooling operation.
(Including the Dry and Auto operations)
②
Setting upper/lower limit temp in heating (
☞
3
)
... Set the range of setting temperature in the heating operation.
③
Temp range setting Enable/Disable (
☞
4
)
... Set whether the limit on the setting temperature range is
enabled or disabled.
Setting temp range
Setting upper/lower limit temp in cooling
Setting upper/lower limit temp in heating
Temp range setting Enable/Disable
Back
Select the item.
Menu
Outdoor unit silent mode timer
Set
Back
Tap
▲▼
to set clock time & tap [Set].
Start time
AM
Outdoor unit silent mode timer
Set
Back
Tap
▲▼
to set clock time & tap [Set].
End time
AM
Summary of Contents for RC-EXZ3A
Page 2: ......