background image

ON : Normal (1ch)

OFF : Customized (2ch)

WIRELESS REMOTE CONTROLLER INSTALLATION MANUAL

WARNING

CAUTION

PFA012D620

Accessories

 
 

Remoto controller holder

1

AAA dry cell battery (RO3)

2

Wood screw for holder

2

Wireless remote controller

1

  Fasten the wiring to the terminal securely and hold the cable securely so as not to apply unexpected stress on the terminal.

  Loose connection or hold will cause abnormal heat generation or fire.

  Make sure the power supply is turned off when electric wiring work. 

  Otherwise, electric shock, malfunction and improper running may occur.

  Install a receiver unit where it is not exposed to direct sunrays or intense light from lighting fixtures.

Please make sure that you have all of the following accessories.

Installation of the controller holder

CAUTION  DO NOT install it on the following places.

1. Places exposed to direct sunlight
3. Places near heat devices
5. High humidity places

• Adjust and keep the holder up right.
• Tighten the screw to the end to avoid scratching the 

remote controller.

• DO NOT attach the holder on plaster wall.

Installation tips for the remote controller holder

1

2. Hot surface or cold surface enough to generate condensation
4. Places exposed to oil mist or steam directly.
6. Uneven surface

1

 

Detach the back lid.

2

 

Insert the batteries. (two AAA batteries)

3

 

Reattach the back lid.

How to insert batteries

Wood screw

Holder for 

remote controller

Ensure the correct 

polarity when

inserting.

FDEN

Up to two receiver or wired remote controller can be installed in one indoor unit group.
When two receivers or wired remote controller are used, it is necessary to change SW on the PCB to set it as 
slave.

Master/Slave setting when using plural remote controllers

Continuation on next page

2

PCB  on  the  receiver  has  the  following 
switches to set the function. 
Default setting is shown with        mark.

Up to 16 indoor units can be connected.

1

 

Connect indoor units with each other with 2-core wires. As for size, refer to the following note.

2

 

The receiver wires must be connected only with the indoor unit that will be operated by the remote 

controller directly.

3

 

Set the indoor unit address with SW2 on the indoor unit PCB from [0] to [F] so as not to duplicate.

Restrictions on the thickness and length of wire 

(Maximun total extension 600m.)  

 

Standard   

Within 100m x 0.3   mm

2

 

 

 

Within 200m x 0.5   mm

2

 

 

 

Within 300m x 0.75  mm

2

 

 

 

Within 400m x 1.25  mm

2

 

 

 

Within 600m x 2.0   mm

2

 

ATTENTION

In  a  system  configured  as  shown  above,  up  to  two  receivers  are  usable.  If  two  receivers  are  used,  it  is 
necessary to designate one of them as a slave by setting SW2. (For the method of changing the setting, refer to 

   

Setting  on  site    .)  Since  other  receivers  are  not  usable,  do  not  couple  the  connectors  for  them.  (Unless  the 
connector is coupled for a receiver, the LED will not be able to make any indication)

Control plural indoor units with one remote controller

Setting on site

1. Remove the front panel.
2. Remove four screws located on the back of the receiver and 

detach the board.

3. Change the setting by the switch on PCB.

4. When switch 1 is turned to off position, change the wireless remote controller setting.

(For the method of changing the setting, refer to   Setting to avoid mixed communication   
on page 4)
Refer to  Wireless remote controller unit operation distance  of

  

3

 FDEN

  in case o

f plural setting.

To change setting

1 2 3 4

Default settings

SW1

Switch

ON
OFF

Receiver Backside

Prevents interference

during plural setting

Receiver master/slave 

setting

Buzzer valid/Invalid

Auto restart

SW1

SW2

SW3

SW4

ON :

OFF :

Master
Slave

ON :

OFF :

Valid
Invalid

ON :

OFF :

Valid
Invalid

Terminal block

Wireless 
remote control unit

Indoor unit  (16)
Address   (F)

Indoor unit  (2)
Address   (1)

Indoor unit  (1)
Address   (0)

Receiver

Receiver

Receiver

Receiver wires must be connected for one unit 
only and leave other indoor units with open 
connectors.

Summary of Contents for RCN-E1R

Page 1: ...nse light from lighting fixtures Please make sure that you have all of the following accessories 2 Installation of the controller holder CAUTION DO NOT install it on the following places 1 Places exposed to direct sunlight 3 Places near heat devices 5 High humidity places Adjust and keep the holder up right Tighten the screw to the end to avoid scratching the remote controller DO NOT attach the hol...

Page 2: ...cessary to designate one of them as a slave by setting SW2 For the method of changing the setting refer to Setting on site Since other receivers are not usable do not couple the connectors for them Unless the connector is coupled for a receiver the LED will not be able to make any indication Control plural indoor units with one remote controller Setting on site 1 Remove the front panel 2 Remove fo...

Page 3: ...p switch is provided on the receiver section of the panel surface When operation from the wireless remote control unit is not possible due to flat batteries a mislaid unit a unit failure you can use it as an emergency means You should operate this switch manually 1 If pressed while the air conditioner is in a halt it will cause the air conditioner to start operation in the automatic mode Wind speed...

Page 4: ...ed How to read the two digit display Pressing ACL and AIR FLOW button at the same time or inserting the batteries with pressing AIR FLOW button will customize the signal ATTENTION When the batteries are removed the setting will return to the default setting Please make sure to reset it when the batteries are replaced Caution Instruct the customer to set the mentioned above when replacing the batte...

Page 5: ...RCN E1R Unit mm PJZ000Z263 ...

Reviews: