– 16 –
HIGH POWER/ECONOMY operation
2
If the air-conditioner is not operating, point the remote control toward the air conditioner, and
Press the ON/OFF button.
Press the HI POWER/ECONO button.
•
When the operating mode is AUTO, COOL or HEAT
Every time the HI POWER/ECONO button is pressed, the display is
switched in the order of:
No display
•
When the operating mode is DRY or PROGRAM TIMER
Every time the HI POWER/ECONO button is pressed, the display is
switched in the order of:
No display
1
(HIGH POWER)
(ECONOMY)
(Normal operation)
(ECONOMY)
(Normal operation)
Concerning ECONOMY operation
Pressing the HI POWER/ECONO button initiates a soft operation with the power suppressed in order to avoid an excessive cooling or
heating. The unit operates 1.5°C higher than the setting temperature during cooling or 2.5°C lower than that during heating. The remote
control
displays and the FAN SPEED display disappears.
NOTE
•
It will go into ECONOMY operation at the next time the air-
conditioner runs in the following case.
1
When the air-conditioner is stopped by ON/OFF button
during ECONOMY operation.
2
When the air-conditioner is stopped in SLEEP or OFF
TIMER operation during ECONOMY operation.
3
When the operation is retrieved from CLEAN operation.
•
When the following operations are set, ECONOMY operation
will be canceled.
1
When the HI POWER/ECONO button is pressed
again.
2
When the operation mode is changed from DRY to
FAN.
•
Not operable while the air-conditioner is OFF.
Concerning HIGH POWER operation
Pressing the HI POWER/ECONO button intensi
fi
es the operating power and initiates powerful cooling or heating operation for 15
minutes continuously. The remote control
displays and the FAN SPEED display disappears.
•
During the HIGH POWER operation, the room temperature is
not controlled. When it causes an excessive cooling or heating,
press the HI POWER/ECONO button again to cancel the HIGH
POWER operation.
•
HIGH POWER operation is not available during the DRY and
the program timer operations.
•
When HIGH POWER operation is set after ON TIMER operation,
HIGH POWER operation will start from the set time.
•
When the following operations are set, HIGH POWER operation
will be canceled.
1
When the HI POWER/ECONO button is pressed again.
2
When the operation mode is changed.
3
When it has been 15 min. since HIGH POWER operation
has started.
•
Not operable while the air-conditioner is OFF.
NOTE
RLC012A012_EN_001-022.indd 16
RLC012A012_EN_001-022.indd 16
2016/07/14 18:19:26
2016/07/14 18:19:26