Preparation of indoor unit
(a)
Mounting of connecting wires
1) Remove the lid.
2) Remove the wiring clamp.
3) Connect the connecting wire securely to the terminal block.
Use cable for interconnection wiring to avoid loosening
of the wires.
CENELEC code for cables Required field cables.
H05RNR3G1.5 (Example) or 245IEC57
H
Harmonized cable type
05
300/500 volts
R
Natural-and/or synth. rubber wire insulation
N
Polychloroprene rubber conductors insulation
R
Standed core
4or5
Number of conductors
G
One conductor of the cables is the earth conductor
(yellow/green)
1.5
Section of copper wire (mm
2
)
•
Connect the connection wire securely to the terminal
block. If the wire is not affixed completely, contact will
be poor, and it is dangerous as the terminal block may
heat up and catch fire.
•
Take care not to confuse the terminal numbers for indoor
and outdoor connections.
•
Affix the connection wire using the wiring clamp.
4) Fix the connecting wire by wiring clamp.
5) Attach the lid.
6) Close the air inlet panel.
Pipe
Drain hose
1. Remove the drain hose.
2. Remove the drain cap.
3. Insert the drain cap.
4. Connect the drain hose.
(b) Shaping the pipe
(c)
Taping of the exterior
•
Hold the bottom of the pipe and change its direction
before stretching it and shaping it.
•
Tape only the portion that runs through the wall.
Always tape the crossover wires with the pipe.
(d) Cautions when piping from the left and the rear center of the unit
[ Top View ]
•
Loosen and remove the
spring-type clamp.
•
Remove with your hand or
a pair of pliers.
•
Use a hexagonal wrench to
correctly insert the drain cap
which was removed in 2.
Caution: Be careful because
if the cap is not inserted
property, water leak may
occur.
•
Loosen the spring-type clamp
and securely insert the drain
hose.
Caution: Be careful because if
the cap is not inserted properly,
water leak may occur.
Left Side Piping
Right Side Piping
Right rear piping
Left rear piping
Left side piping
Right side piping
Lid
Screw *
Clamp
Terminal block
[ Procedure for exchanging the drain hose ]
Left downward
Right
Rear
Downward
Left rear
Left
Piping is possible in the rear, left,
left rear, left downward, right or
downward direction.
Wall
Gutter
Pipes storage area
•
Do not place the power supply cords above the gutter, because the
air conditioner is structured in a way where condensation on the
back side is collected in to the drain pan before drainage.
•
Do not make traps in the drain hose line.
Declining slope
Inverted slipe
Trap
*Leave space to allow removal of this screw after installation.
For power supply, indoor outdoor
2
Blue
For power supply, indoor outdoor
1
Brown