3
-
2
SELECTION DATA
2.1 Specifications
Model
SRK10CFV-4 (Indoor unit)
SRC10CFV-4 (Outdoor unit)
(2) The operation data are applied to the 220 V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7.5 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, when it is 7.5 to 15 m, add 10 g refrigerant per meter.
(4) Expressed in sound pressure level.
Notes (1) The data are measured at the following conditions.
Item
Model
SRK10CFV-4
SRC10CFV-4
Cooling capacity
(1)
BTU
9000
Power source
1 Phase, 220V, 50Hz
Cooling input
kW
0.73
Running current (Cooling)
A
3.4
Inrush current
A
18
COP (In cooling)
3.62
Noise level
(4)
dB
39
45
Exterior dimensions
mm
268
×
790
×
199
540
×
780
×
290
Height
×
Width
×
Depth
Color
Fine snow
Stucco white
Net weight
kg
8.5
30
Refrigerant equipment
–
RSA201A018
Compressor types & Q’ty
Motor
kW
–
0.69
Starting method
–
Line starting
Heat exchanger
Louver fins & inner grooved tubing
Louver fins & inner grooved tubing
Refrigerant control
Capillary tubes
Refrigerant
(3)
kg
R22 0.9 (Pre-Charged up to the piping length of 7.5m)
Refrigerant oil
R
0.35 (SUNISO 4GSI or ATMOS NM56)
Air handling equipment
Tangential fan
×
1
Propeller fan
×
1
Fan type & Q’ty
Motor
W
16
14
Air flow (at High)
CMM
9.0
26.5
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Wireless-Remote control
–
Operation switch
Room temperature control
Microcomputer thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow),
–
HI POWER (Green), 3D AUTO (Green)
Safety equipment
Frost protection,
Internal thermostat (for compressor)
Fan motor error protection
O.D
mm (in)
Liquid line: ø6.35 (1/4") Gas line: ø9.52 (3/8")
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.4 m
–
Gas line : 0.33 m
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source cord
2.5 m (3 cores with Earth)
Size
×
Core number
1.5 mm
2
×
3 cores (Including earth cable)
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Optional parts
–
Connection
wiring
Refrig
erant
piping
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27
°
C
19
°
C
35
°
C
24
°
C
ISO-T1, JIS C9612
(220V)
Operation
data
(1)
All manuals and user guides at all-guides.com