28
-
(5)
Inspection procedures of indoor electrical equipment
NO
YES
YES
YES
NO
NO
Is fuse (3.15A) blown?
Indoor electrical equipment
are normal.
Is voltage applied between
terminals
1
~
2
on terminal
block? (AC 220/230/240V)
Is DC 0~12V detected between
terminals
2
~
3
on terminal
block?
Replace fuse.
Replace PCB.
Replace PCB.
Notes (1) Since the communication timing signal is transmitted only when the 52C is turned ON, check it under the operating condition.
(2) Check the voltage on the terminal block.
¡
Power supply: Between
1
~
2
(AC 220/230/240V)
¡
Signal: Between
2
~
3
(Changing between DC 0~Approx. 12V)
(6)
How to make sure of remote controller
(1)
Is remote
controller
normal?
YES
Again pushing
operating switch
Operating the unit?
NO
Does unit ON/OFF
button operates?
Operating the unit.
NO
NO
YES
YES
Remote controller
defects
Abnormality is not
found.
Replace the display.
Control problem on
indoor unit
Is the unit
operable with remote
controller?
Defective remote
controller
NO
YES
Normal
Note (1) Check method of remote controller
(a) Press the reset switch of the remote controller.
(b) If all LCD are displayed after zero (0) display, it is basically normal.
LO
MED
HI
AUTO
HI POWER
ECONO
ON
OFF
AM
PM