-
19
-
27.5
25.5
19.5
18
30
4.11 Outline of clean operation
COOL,DRY,AUTO (COOL,DRY); after operation has stopped, the moisture inside the dryer air conditioner, controls the production of
fungus etc.
(1)
Operating condition
‘Clean’ is switched ON, when the air conditioner receives a STOP signal.
(2)
Detail of operation
(3)
Reset condition
When control finishes 120 minutes after the Clean operation starts. When the stop signal is received from the remote control.
Compressor
OFF
Indoor fan motor
Speed 1
Outdoor fan motor
OFF
Flap
Fully closed
4.10 Outline of automatic operation
(1)
Determination of operation mode
The unit checks the room temperature and the outdoor air temperature after operating the indoor and outdoor blowers for 20
seconds, determines the operation mode and the room temperature setting correction value, and then begins in the automatic
operation.
Heating
Dehumidifying
Cooling
Room temperature (˚C)
Outdoor temperature (˚C)
(2)
The unit checks the temperature every 30 minutes after the start of operation and, if the result of check is not same as the previous
operation mode, changes the operation mode.
(3)
When the unit is started again within 30 minutes after the stop of automatic operation or when the automatic operation is selected
during heating, cooling or dehumidifying operation, the unit is operated in the previous operation mode.
(4)
Setting temperature can be adjusted within the following range. There is the relationship as shown below between the signals of the
wireless remote control and the setting temperature.
Signals of wireless remote control (Display)
–6
–5
–4
–3
–2
–1
±
0
+1
+2
+3
+4
+5
+6
Setting
Cooling
18
19
20
21
22
23
24
25
26
27
28
29
30
temperature
Dehumidifying
18
19
20
21
22
23
24
25
26
27
28
29
30
Heating
20
21
22
23
24
25
26
27
28
29
30
31
32