- 58 -
(11) Remote controller failure diagnosis procedure
No
Is the remote
controller
normal after
reset?
Note (1)
No
No
Yes
●
Low battery of remote controller
●
Defective remote controller
Replace
Restart
Does the air
conditioner
operate?
Yes
Yes
No error
Defective PCB of indoor
unit
Can the air
conditioner operate
when the back-up
switch is used?
Replace the wireless
receiving part.
Defective wireless receiving
part
Yes
Can the air conditioner
operate when the
remote controller is
used?
No
Defective remote controller
Replace
Note (1)
(a) Press the ACL switch on the remote controller.
(b) If the set temperature displayed is 0
℃
and the current
time displayed is 12:00, it indicates there are no
obvious problems.
Summary of Contents for SRC20MA-S