2.2 Range of usage & limitations
Indoor return air temperature
(Upper, lower limits)
Refrigerant line (one way) length
Max. 15m
SRK20ZFX-S, 25ZFX-S, 35ZFX-S
SRK50ZFX-S
Cooling operation: Approximately 21 to 32
°
C
Heating operation: Approximately 15 to 30
°
C
Cooling operation: Approximately -15 to 43
°
C
Heating operation: Approximately -5 to 21
°
C
Power source voltage
Rating
±
10%
Voltage at starting
Min. 85% of rating
Frequency of ON-OFF cycle
ON and OFF interval
Max. 3 minutes
Max. 4 times/h
(Inching prevention: 10 min.)
Max. 7 times/h
(Inching prevention: 5 min.)
Outdoor air temperature
(Upper, lower limits)
Vertical height difference between
outdoor unit and indoor unit
Max. 10m (Outdoor unit is higher)
Max. 10m (Outdoor unit is lower)
Max. 25m
Max. 15m (Outdoor unit is higher)
Max. 15m (Outdoor unit is lower)
Item
Models
2.3 Exterior dimensions
(1)
Indoor unit
Models All models
840
298
A
Piping hole right
259
9
44
right: 67
left : 60
3
60
60
14.5
813
60
3
44
44
60
60
VIEW A
44.5
47.5
220.5
50
207.5
73.5
53.5
Piping hole (ø65)
Piping hole (ø65)
Indoor unit
Installating board
Drain hose 515 (ø16)
Piping for gas 533.5
)
(
20,25,35: ø9.52
50: ø12.7
Piping for liquid 603.5 (ø6.35)
63.5
8.5
5.3
284.2
44.5
73.5
182.5
50
450
693
25