5.6 Standard running data:
SRK25QA-S
SRK35QA-S
High pressure (MPa)
Cooling
-
-
Heating
2.2-2.9
2.0-3.2
Low pressure (MPa)
Cooling
1.0-1.2
0.9-1.2
Heating
-
-
Temp. difference between inlet
and outlet air of indoor unit (
℃
)
Cooling
9-11
8-14
Heating
9-16
10-21
Operating current (A)
Cooling
1.4-3.5
1.3-5.3
Heating
1.7-4.6
1.6-6.5
Notes:
①
The above data complies with the standard:
and is measured at the following ambient temperature:
indoor side: cooling……27
℃
DB, 19
℃
WB; heating……20
℃
DB
outdoor side: cooling……35
℃
DB, 24
℃
WB; heating……7
℃
DB, 6
℃
WB
②
The length of the pipe between the indoor and outdoor units is 5 meters in the test. The
length of the pipe supplied with the appliance may vary.