-3-
2.1.2 Model:
SRK35QA–S (Indoor unit)
SRC35QA–S (Outdoor unit)
Item
Unit
Indoor unit SRK35QA–S
Outdoor unit SRC35QA–S
Net weight
kg
9.5
35
Machine
dimension
mm
790×222×268
780×290×540
Package
dimension
Length× Width
×Height
830×340×280
920×380×590
Color
White
Ash-colored
Fan
Through-flow type, AS resin + glass
fiber
Axial flow type, AS resin + glass
fiber (embedded damping spindle
sleeve)
Air flow
m
3
/h
520
1940
Noise in cool
room
dB(A)
Hi/Me/Lo: 40/33/25
47
Noise in warm
room
dB(A)
Hi/Me/Lo: 39/35/27
48
Fan motor
Nominal value
16W, 4-step capacitor type
asynchronous motor, insulation
grade E
24W, DC motor, insulation grade E
Power of motor
W (reference
value)
40
20
Power of electric
control
W (reference
value)
2
7.5
Power supply and
power cord
Single-phase, 220V, 50Hz and 3-core, 1.0mm
2
, 250V, 10A, 2m, w/o plug
Heat exchanger
Spiral, hydrophilic, 3-folded,
16-section, 2-row, 452-fin, 1-4
circuit
Child heat exchanger: Spiral,
hydrophilic, 1-row, 4-section,
408-fin
Spiral, hydrophilic, 20-section,
2-row, 1221-fin, 2-1 circuit
Pf1.4
Compressor
Nominal value
THACOM RM - B5077MDE2, 527W, DC frequency conversion
compressor, insulation grade E
Refrigerating
machine oil
ml
300, DIAMOND FREEZE MA68
Refrigerant
controller
Electronic expansion valve (Φ1.5mm) + hush pipe
Refrigerant
g
R-410A, 900g, addition/reduction not needed within the use range of 15m
Operating
pressure limit
MPa
Max.: 4.15, Min.: 1.47
Air filter
Mould-proof air filter
Accessories and
quantity
Indoor unit 1, mounting plate 1, tapping screw 5, battery 2, use and
installation manual 1, remote controller 1, outdoor unit 1, Drain elbow 1,
Water shutoff plug 1
Operation control
devices
Wireless remote controller, electronic thermostat controlling room
temperature, microcomputer controlling defrosting
Safety devices
Serial signal protection, fan error protection, compressor over heat
protection, high voltage protection, over current protection, etc.
* The nominal values of “Noise in cool room” and “Noise in warm room” in the above table are tested in a dead
room.
Item
Unit
Rating cooling
Rating heating
Capacity
W
3500
4000
Power
W
1020
1100
Energy efficiency ratio
3.43
3.64
Energy efficiency grade
Grade A (European norm)
Note (1) The data are measured at the following conditions. The pipe length is 5m.
Item
Operation
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
DB
WB
Cooling
27
℃
19
℃
35
℃
24
℃
Heating
20
℃
—
7
℃
6
℃
Low temperature Heating
20
℃
—
2
℃
1
℃
(2) The operation data are applied to the 220Vdistricts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
Summary of Contents for SRC25QA-S
Page 10: ... 7 3 ELECTRICAL WIRING DIAGRAM 3 1 Circuit diagram 25QA S ...
Page 11: ... 8 3 2 Circuit diagram 35QA S ...
Page 22: ... 19 B Prevent Range I in jiggle operation from changing to Range C operation ...
Page 58: ... 55 12 Check method for outdoor unit 1 Circuit diagram of 25QA S outdoor unit ...
Page 59: ... 56 2 Circuit diagram of 35QA S outdoor unit ...
Page 81: ... 78 ...
Page 86: ... 83 RAC SRK35QA S PANEL FAN ASSY ...
Page 88: ... 85 20 21 RYD436A021 LOUVER ASSY 1 20 RYD436A020 LOUVER 12 21 RYD129A048 PLATE CONNECTING 2 ...
Page 92: ... 89 ...
Page 94: ... 91 ...
Page 98: ... ...
Page 100: ... 19 RYF937A002A CLAMP WIRE 1 ...