-75-
b) Charge hose (pressure resistant fluorocarbon hose) and sealing ring
● Thickness 1/48, multiple lengths available
● Hose with the pressure resistance property higher than 5.2MPa (52kg/cm
2
G)
● In general, only one end has fixture.
(4) Manifold pressure gauge
● The most important servicing tool for coolers and air conditioners
● It is widely used to check gas pressure when R410A is being charged/recovered.
(5) Conduit needle valve
a) To recover R410A from the equipment without gas charging or recovery port, use the tool
to drill a hole in the copper pipe. There are a number of types available on the market which
have different names.
b) The edge of needle may be damaged easily, so such valve should be treated as
semi-supplies.
c) When the vacuum level rises, air will be absorbed into the hole easily. Therefore, please
operate carefully.
(6) Vacuum pump
For evacuating the recovery device and the recovery cylinder.
Hose
sealing ring
Fixture
Compound
pressure gauge
Pressure gauge
Disconnecting valve
Charge hose
Manifold
pressure gauge
Punch pliers
Needle valve
Air inlet
Vent
Summary of Contents for SRC25QA-S
Page 10: ... 7 3 ELECTRICAL WIRING DIAGRAM 3 1 Circuit diagram 25QA S ...
Page 11: ... 8 3 2 Circuit diagram 35QA S ...
Page 22: ... 19 B Prevent Range I in jiggle operation from changing to Range C operation ...
Page 58: ... 55 12 Check method for outdoor unit 1 Circuit diagram of 25QA S outdoor unit ...
Page 59: ... 56 2 Circuit diagram of 35QA S outdoor unit ...
Page 81: ... 78 ...
Page 86: ... 83 RAC SRK35QA S PANEL FAN ASSY ...
Page 88: ... 85 20 21 RYD436A021 LOUVER ASSY 1 20 RYD436A020 LOUVER 12 21 RYD129A048 PLATE CONNECTING 2 ...
Page 92: ... 89 ...
Page 94: ... 91 ...
Page 98: ... ...