25
-
'14 • SRK-T-170
EARTHING WORK
○
Earth work shall be carried out without fail in order to prevent
electric shock and noise generation.
○
The connection of the earth cable to the following substances
causes dangerous failures, therefore it shall never be done.
City water pipe, Town gas pipe, TV antenna, lightning
conductor, telephone line, etc.
HOW TO RELOCATE OR DISPOSE OF THE UNIT
○
In order to protect the environment, be sure to pump down (recovery of refrigerant).
○
Pump down is the method of recovering refrigerant from the indoor unit to the outdoor unit
when the pipes are removed from the unit.
<How to pump down>
①
Connect charge hose to check joint.
②
Liquid side : Close the liquid valve with hexagon wrench key.
Gas side : Fully open the gas valve.
Carry out cooling operation. (If indoor temperature is low, operate forced cooling operation.)
③
After low pressure gauge become 0.01MPa, stop cooling operation and close the gas valve.
○
Forced cooling operation
Turn off power supply. Turn on power supply again after a while. Then, press the ON/OFF
button continuously for at least 5 seconds. (The operation will start.)
Unit ON/OFF button
○
Conventionally, operate the wireless
remote control by holding in your hand.
○
Avoid installing it on a clay wall etc.
②
Wireless remote control
④
Battery
Cover
INSTALLATION OF WIRELESS REMOTE CONTROL
Mounting method of battery
Fixing to pillar or wall
○
Uncover the wireless remote control, and
mount the batteries
〔
R03 (AAA, Micro),
×
2 pieces
〕
in the body regularly.
(Fit the poles with the indication
marks,
+
&
−
without fail)
CAUTION
Do not use new and
old batteries together.
Wood screws (Option parts)
Remote control holder
(Option parts)
g
h
ø3.5 X 16
How to remove and install the front panel
Set screws
Push
Set screws
Latches
Front panel
○
Removing
Remove the air inlet panel.
Remove the 2 set screws.
Remove the 3 latches in the upper section.
Move the lower part of the panel forward and push upwards to remove.
1
2
3
4
○
Fitting
Do remove the air filter.
Cover the body with the front panel.
Fit the 3 latches in the upper section.
Tighten the 2 set screws.
Fit the air filter.
Fit the air inlet panel.
1
2
3
4
5
6