27
-
'14 • SRK-T-170
○
Matters of special notice when piping from left or central/rear of the unit.
[Top view]
Left-hand-sided piping
Piping in the left rear direction
Piping in the left direction
Piping in the right direction
Piping in the right rear direction
Higher than specified
Wavy
Right
Rear
Downward
Left rear
Left
Left downward
Right-hand-sided piping
Gutter
Pipe accommodating section
Since this air conditioner has
been designed to collect dew
drops on the rear surface to
the drain pan, do not attach
the power cord above the
gutter.
The gap to the ground is
5 cm or less.
The drain hose tip is
in the gutter.
The drain hosetip is
in water.
Shaping of pipings
Taping of the exterior
Piping
Drain hose
Installing the support of piping
Drainage
○
Hold the bottom of the
piping and fix direction
before stretching it and
shaping it.
○
Tape only the portion that
goes through the wall.
○
Always tape the wiring
with the piping.
Sufficient care must be taken not to damage the panel
when connecting pipes.
Fixing of indoor unit
Installation Steps
①
Pass the pipe through the hole
in the wall, and hook the upper
part of the indoor unit to the
installation board.
②
Gently push the lower part to
secure the unit.
Odor from
the gutter
[Drain hose changing procedures]
1. Remove the drain hose.
2. Remove the drain cap.
○
Remove it with hand or pliers.
○
Remove the screw and drain hose,
making it rotate.
3. Insert the drain cap.
4. Connect the drain hose.
○
Insert the drain cap which was removed
at procedure “2” securely using a
hexagonal wrench etc.
Note: Be careful that If it is not inserted
securely, water leakage may occur.
○
Insert the drain hose securely, making
rotate. And install the screw.
Note: Be careful that If it is not inserted
securely, water leakage may
occur.
○
How to remove the indoor unit from the installation board
The marked portion of the indoor
unit base lower latch
Lid (Right)
Lid (Left)
①
Remove the lid both right and left.
②
Push up at the marked portion of the
indoor unit base lower latch, and
slightly pull it toward you.
(both right and left hand sides)
(The indoor unit base lower latch can
be removed from the installation board)
③
Push up the indoor unit upward so that
it can be removed from installation
board.
Piping is possible in the rear, left, left rear,
left downward, right or downward direction.
○
Pour water to the drain pan located under the heat exchanger,
and ensure that the water is discharged outdoor.
○
When extended drain hose is present inside the room,
insulate it securely with heat insulator available in the market.
○
Arrange the drain hose in a downward angle.
○
Avoid the following drain piping.
Go through all installation steps and check if the drainage is
all right. Otherwise, water leak may occur.
CAUTION
Indoor unit
Installation board
Wall
Indoor unit base
lower latch
Latch (2
location
s)
Installation
board
When pulling out a pipe from right or left, remove the
styrofoam parts from the inside.
CAUTION