'14 • SRK-T-170
Model SRK25ZXA-S
Model
Item
SRK25ZXA-S
Indoor unit
SRK25ZXA-S
Outdoor unit
SRC25ZXA-S
Power source
Single Phase, 220 - 240V, 50Hz
Operation
data
Nominal cooling capacity (range)
kW
2.5 (0.9 (Min.) - 4.0 (Max.))
Nominal heating capacity (range)
kW
3.5 (1.1 (Min.) - 4.3 (Max.))
Power
consumption
Cooling
kW
0.56 (0.21 - 1.4)
Heating
0.91 (0.28 - 1.37)
Max power consumption
1.63
Running
current
Cooling
A
2.9 / 2.8 / 2.7 (220 / 230 / 240V)
Heating
4.4 / 4.2 / 4.0 (220 / 230 / 240V)
Inrush current, max current
2.9 / 2.8 / 2.7 (220 / 230 / 240 V) Max. 9
Power factor
Cooling
%
88
Heating
94
EER
Cooling
4.46
COP
Heating
3.85
Sound power level
Cooling
dB(A)
53
54
Heating
53
59
Sound pressure level
Cooling
Hi: 37 Me: 29 Lo: 22
43
Heating
Hi: 37 Me: 31 Lo: 25
48
Silent mode sound pressure level
—
—
Exterior dimensions (Height x Width x Depth)
mm
298 x 798 x 231
540 x 780 (+62) x 290
Exterior appearance
White
Stucco white
Net weight
kg
10.5
34.5
Compressor type & Q'ty
—
RM-B5077MDE2 (Rotary type) x 1
Compressor motor (Starting method)
kW
—
0.75 (Inverter driven)
Refrigerant oil (Amount, type)
—
0.3 (DIAMOND FREEZE MA68)
Refrigerant (Type, amount, pre-charge length)
kg
R410A 1.150 in outdoor unit (incl. the amount for the piping of 10m)
Heat exchanger
Louver fins & inner grooved tubing
M fins & inner grooved tubing
Refrigerant control
Capillary tubes + Electronic expansion valve
Fan type & Q'ty
Tangential fan x 1
Propeller fan x 1
Fan motor (Starting method)
W
30 x1 (Direct drive)
24 x1 (Direct drive)
Air flow
Cooling
m
3
/min
Hi: 7.9 Me: 6.1 Lo: 4.1
30.0
Heating
Hi: 8.0 Me: 7.9 Lo: 4.1
28.7
Available external static pressure
Pa
0
0
Outside air intake
Not possible
—
Air filter, Quality / Quantity
Polypropylene net (washable)
—
Shock & vibration absorber
Rubber sleeve (for fan motor)
Rubber sleeve (for fan motor & compressor)
Electric heater
—
—
Operation
control
Remote control
Wireless remote control
Room temperature control
Microcomputer thermostat
Operation display
RUN, TIMER, HI POWER, ECONO, CLEAN, Temperature: White
Safety equipments
Compressor overheat protection, Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection (High pressure control), Cooling overload protection
Installation
data
Refrigerant piping size (O.D)
mm
Liquid line :
φ
6.35 (1/4") Gas line :
φ
9.52 (3/8")
Connecting method
Flare connection
Flare connection
Attached length of piping
m
Liquid line : 0.52 / Gas line : 0.47
—
Insulation for piping
Necessary (Both sides), independent
Refrigerant line (one way) length
m
Max. 15
Vertical height diff. between O.U. and I.U.
m
Max. 10 (Outdoor unit is higher) / Max. 10 (Outdoor unit is lower)
Drain hose
Hose connectable (VP 16)
Holes
φ
20 x 2 pcs
Drain pump, max lift height
mm
—
—
Recommended breaker size
A
16
L.R.A. (Locked rotor ampere)
A
3.9 / 3.8 / 3.6 (220 / 230 / 240 V)
Interconnecting wires
Size x Core number
1.5mm
2
x 4 cores (Including earth cable) / Terminal block (Screw fixing type)
IP number
IPX0
IPX4
Standard accessories
Mounting kit
Option parts
—
Note (1) The data are measured at the following conditions.
item
operation
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
DB
WB
Cooling
27˚C
19˚C
35˚C
24˚C
ISO5151-T1
Heating
20˚C
—
7˚C
6˚C
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat
higher due to ambient conditions.
(4) Select the breaker size according to the own national standard.
(5) The refrigerant quantity to be charged includes the refrigerant in 10 m connecting piping.
(purging is not required even for the short piping. )
If the piping length is longer, when it is 10 to 15 m, add 20 g refrigerant per meter.
The pipe length is 7.5m.
1. SPECIFICATIONS