– 13 –
(Units of ten minutes)
(Units of ten minutes)
ON-TIMER operation
1
2
How to cancel
Press the CANCEL button to turn off the timer
indicator.
Example: In the case the preferred room temperature is required at 8:00.
Press the ON-TIMER button.
ON TIMER indicator
is blinking.
3
■
Operation starts 5 to 60 minutes before the set time so that the room temperature reaches the optimum temperature at the set time.
ON-TIMER operation can be set regardless of whether the air-conditioner is running or not.
Press the “
or
” button.
Every time the
button is pressed, the display is switched in the order of:
Every time the
button is pressed, the display is switched in the order of:
Set at 8:00.
Press the ON TIMER button.
The display changes from blinking to steady lighting and the setting is complete.
The timer light (yellow) is on.
The operation stops if it is set during operation.
Changing of set time
Set a new time by using the ON-TIMER button.
•
Operation starts 5 to 60 minutes before the set time.
•
The timer light (yellow) goes out at the set time.
•
Make sure to press the button within 60 seconds from the last operation in step 2,
otherwise the setting is not completed.
•
The current time is not displayed during ON-TIMER operation.
Comfort Start-up
In ON TIMER operation, the unit starts the operation a little earlier, so that the
room can approach optimum temperature at ON time. This is so called
“Comfort start-up”.
•
Mechanism
The room temperature is checked
60 minutes before the ON time.
Depending on the temperature at
that time, the operation starts 5 to
60 minutes before the timer is at
ON.
•
The function is available for both
COOL and HEAT operation
mode (including AUTO). It does
not work for DRY mode.
In COOL operation
(Stop) Operation starts
▼
Check the room
temp. 60 mins.
before.
Set time
▼
(Operation)
Set temperature
Unit display section
TIMER light (yellow)
NOTE
0:00
0:10
0:20
...
1:00
1:10
0:00
23:50
23:40
...
23:00
22:50
RFB012A003_EN_001_024
08/07/2009, 10:03