'14 • SRF-T-163
(18) DRED
This air conditioner complies with the DRED (Demand Response Enabling Devices) standard AS/NZS4755.3.1 and
supports below demand response modes 1, 2, and 3 (DRM1, 2, and 3). Since the air conditioner limits the electric power
or energy by receiving the DRED input signal, the feeling of cooling operation or heating operation may deteriorate during
that time. The outdoor unit of this air conditioner is equipped with a terminal block for DRED input and supports ELV (Extra-
Low Voltage) complying with AS/NZS60335.1.
Under DRED mode, RUN light and TIMER light blink alternately as shown. When the Defrost function becomes effective
during DRED operation, the TIMER light blinks quickly.
RUN light
ON
OFF
2 sec.
2 sec.
2 sec.
2 sec.
ON
OFF
TIMER light
Display in DRED mode
Display in DRED mode during Defrost operation
RUN light
ON
OFF
2 sec.
2 sec.
0.5 sec.
2 sec.
0.5 sec.
TIMER light
ON
OFF
Table
AIR
CONDITIONER
DEMAND
RESPONSE
MODES
Demand
response
mode
(DRM)
Description of operation in this mode
Remarks
DRM1
Compressor off
DRM2
Compressor speed control
The air conditioner continues to cool or heat during
the demand response event, but the electrical energy
consumed by the air conditioner in a half hour period
is not more than 50% of the total electrical energy that
would be consumed if operating at the rated capacity
in a half hour period.
DRM3
Compressor speed control
The air conditioner continues to cool or heat during
the demand response event, but the electrical energy
consumed by the air conditioner in a half hour period
is not more than 75% of the total electrical energy that
would be consumed if operating at the rated capacity
in a half hour period.
Summary of Contents for SRF25ZMXA-S
Page 2: ......
Page 3: ... 14 SRF T 163 TECHNICAL MANUAL ...
Page 12: ... 10 14 SRF T 163 3 Remote control Unit mm 60 26 167 a Wireless remote control ...
Page 93: ... 91 14 SRF T 163 WARING CAUTION 3 Super link E board SC ADNA E F ...
Page 94: ... 92 14 SRF T 163 ...
Page 100: ... 98 14 SRF T 163 CRCE0010 12 13 14 3 2 1 4 4 5 10 10 4 7 8 9 6 15 16 11 CONTROL PARTS SET ...
Page 106: ... 104 14 SRF T 163 CRCE0010 12 13 14 3 2 1 4 4 5 10 10 4 7 8 9 6 15 16 11 CONTROL PARTS SET ...
Page 112: ... 110 14 SRF T 163 CRCE0010 12 13 14 3 2 1 4 4 5 10 10 4 7 8 9 6 15 16 11 CONTROL PARTS SET ...
Page 114: ... 112 14 SRF T 163 CRBE0276 6 13 11 12 15 16 3 17 14 2 4 9 8 7 5 1 8 8 10 PANEL FAN ASSY ...
Page 118: ... 116 14 SRF T 163 CRBE0276 6 13 11 12 15 16 3 17 14 2 4 9 8 7 5 1 8 8 10 PANEL FAN ASSY ...
Page 122: ... 120 14 SRF T 163 CRBE0315 9 13 15 16 14 17 7 6 4 1 8 3 11 5 18 10 10 10 2 12 PANEL FAN ASSY ...