'13•SRK-T-141
Model
Item
SRK09CMP-3
Indoor unit
SRK09CMP-3
Outdoor unit
SRC09CMP-3
Cooling capacity (1)
W
2500
Power supply
1
Phase, 220 - 240V, 50Hz
Operation
data (1)
Power
consumption
Cooling
kW
0.925
Running
current
Cooling
A
4.7 / 4.6
Inrush current
21.0
COP
Cooling
2.70
Noise
level
Cooling
Sound level
dB(A)
43
50
Exterior dimensions (Height x Width x Depth)
mm
262 x 615 x 210
435 x 645 (+50) x 275
Exterior appearance
(Munsell color)
Fine snow
(8.0Y 9.3/0.1) near equivalent
Stucco white
(4.2Y 7.5/1.1) near equivalent
Net weight
kg
6
22
Refrigerant
equipment
Compressor type & Q'ty
—
RMC201A054 (Rotary type) x 1
Motor (Starting method)
kW
—
0.7 (PSC)
Refrigerant oil
0.28 (SUNISO 4GSI or ATMOS NM56M)
Refrigerant (3)
kg
R22 0.41 (Pre-Charged up to the piping length of 5.0m)
Heat exchanger
Louver fins & inner grooved tubing
Louver fins & inner grooved tubing
Refrigerant control
Capillary tubes
Air handling
equipment
Fan type & Q'ty
Cross flow fan x 1
Propeller fan x 1
Motor
W
17
22
Air flow
Cooling
m
3
/min
9.0
23.0
Fresh air intake
Not possible
—
Air filter, Quality / Quantity
Polypropylene net (washable) x 1
—
Shock & vibration absorber
—
Cushion rubber (for compressor)
Operation
control
Operation switch
Wireless-Remote control
—
Room temperature control
Microcomputer thermostat
—
Operation Display
RUN : Green, TIMER : Yellow
Safety devices
Compressor overheat protection, Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Cooling overload protection
Installation
data
Refrigerant piping size (O.D)
mm
Liquid line:
φ
6.35 (1/4") Gas line:
φ
9.52 (3/8")
Connecting method
Flare connecting
Attached length of piping
m
Liquid line : 0.46
Gas line : 0.40
—
Insulation for piping
Necessary (Both sides), independent
Refrigerant line (one way) length
m
Max. 15
Vertical height difference between
outdoor unit and indoor unit
Max.5 (Outdoor unit is higher)
Max.5 (Outdoor unit is lower)
Drain hose
Connectable (VP 16)
—
Power cable
—
Recommended breaker size
A
10
Connection wiring
Size x Core number
1.5mm
2
x 3 cores (Including earth cable)
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Option parts
—
Note (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
DB
WB
Cooling
27˚C
19˚C
35˚C
24˚C
ISO-T1, JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220 / 230V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 5.0m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is 5m to 15m, additional refrigerant is 10g per each 1m longer than 5m.
The pipe length is 5.0m.
Summary of Contents for SRK05CM
Page 2: ... 13 SRK T 141 TECHNICAL MANUAL ...
Page 73: ... 72 13 SRK T 141 CRBE0358 7 4 12 6 1 14 15 7 6 5 8 3 6 9 6 13 11 10 2 PANEL FAN ASSY ...
Page 77: ... 76 13 SRK T 141 CRBE0358 7 4 12 6 1 14 15 7 6 5 8 3 6 9 6 13 11 10 2 PANEL FAN ASSY ...
Page 81: ... 80 13 SRK T 141 CRBE0361 7 4 12 6 1 14 15 7 6 5 8 3 6 9 6 13 11 10 2 PANEL FAN ASSY ...
Page 85: ... 84 13 SRK T 141 CRBE0358 7 4 12 6 1 14 15 7 6 5 8 3 6 9 6 13 11 10 2 PANEL FAN ASSY ...
Page 89: ... 88 13 SRK T 141 CRBE0358 7 4 12 6 1 14 15 7 6 5 8 3 6 9 6 13 11 10 2 PANEL FAN ASSY ...