'13•SRK-T-141
– 27 –
Preparation of indoor unit
①
Mounting of connecting wires
ⓐ
Remove the lid.
ⓑ
Remove the wiring clamp.
ⓒ
Connect the connecting wire securely to the terminal block.
Use cable for interconnection wiring to avoid loosening of the wires.
CENELEC code for cables Required
fi
eld cables.
7
5
C
E
I
5
4
2
r
o
)
e
l
p
m
a
x
E
(
5
.
1
G
4
R
N
R
5
0
H
H Harmonized cable type
05 300/500 volts
R Natural-and/or synth. rubber wire insulation
N Polychloroprene rubber conductors insulation
R Standed core
s
r
o
t
c
u
d
n
o
c
f
o
r
e
b
m
u
N
5
r
o
4
G One conductor of the cables is the earth conductor (yellow/green)
1.5 Section of copper wire (mm
2
)
•
Connect the connection wire securely to the terminal block. If
the wire is not af
fi
xed completely, contact will be poor, and it
is dangerous as the terminal block may heat up and catch
fi
re.
•
Take care not to confuse the terminal numbers for power
source indoor and outdoor connections.
•
Earth lead wire shall be longer than the other lead wires for the electrical
safety in case of the slipping out of the cord from the anchorage.
•
The earth line of power cord must be properly earthed.
L
N
Connecting diagram.
Power supply
source
Terminal on the indoor unit
L 2/N
2
N
L
1
1
Terminal on the outdoor unit
•
Af
fi
x the connection wire using the wiring clamp.
ⓓ
Fix the connecting wire by wiring clamp.
ⓔ
Attach the lid.
②
Shaping the pipe
③
Taping of the exterior
•
Hold the bottom of the pipe and change its direction
before stretching it and shaping it.
•
Tape only the portion that runs through the wall.
Always tape the crossover wires with the pipe.
④
Cautions when piping from the left and the rear center of the unit
[ Top View ]
•
Remove the screw and
pull the drain hose, while
twisting.
•
Remove it with hand or
pliers.
•
Insert the drain cap which
was removed at procedure “2”
securely using a hexagonal
wrench etc.
Note: Be careful that if it is not
inserted securely, water leakage
may occur.
•
Insert the drain hose securely,
push the drain hose while
twisting. Install the screw.
Note: Be careful that if it is
not inserted securely, water
leakage may occur.
Piping is possible in the rear,
left, left rear, left downward,
right or downward direction.
•
Do not place the power supply cords above the gutter, because the
air conditioner is structured in a way where condensation on the back
side is collected in to the drain pan before drainage.
•
Do not make traps in the drain hose line.
Declining slope
Inverted slipe
Trap
* Leave space to allow
removal of this screw
after installation.
[ Drain hose changing procedures ]
Pipe
Drain hose
Terminal block
Screw*
Clamp
Lid
Left Side Piping
Right Side Piping
Left rear piping
Left side piping
Right rear piping
Right side piping
Right
Left
Left rear
Rear
Downward
Left downward
1. Remove the drain hose.
2. Remove the drain cap.
3. Insert the drain cap.
4. Connect the drain hose.
Gutter
Pipes storage area
Wall
RMA012A065A-067A_Install_EN.indd 27
1/25/2013 1:12:43 PM
Summary of Contents for SRK05CM
Page 2: ... 13 SRK T 141 TECHNICAL MANUAL ...
Page 73: ... 72 13 SRK T 141 CRBE0358 7 4 12 6 1 14 15 7 6 5 8 3 6 9 6 13 11 10 2 PANEL FAN ASSY ...
Page 77: ... 76 13 SRK T 141 CRBE0358 7 4 12 6 1 14 15 7 6 5 8 3 6 9 6 13 11 10 2 PANEL FAN ASSY ...
Page 81: ... 80 13 SRK T 141 CRBE0361 7 4 12 6 1 14 15 7 6 5 8 3 6 9 6 13 11 10 2 PANEL FAN ASSY ...
Page 85: ... 84 13 SRK T 141 CRBE0358 7 4 12 6 1 14 15 7 6 5 8 3 6 9 6 13 11 10 2 PANEL FAN ASSY ...
Page 89: ... 88 13 SRK T 141 CRBE0358 7 4 12 6 1 14 15 7 6 5 8 3 6 9 6 13 11 10 2 PANEL FAN ASSY ...