-
-
'14•SRK-T-153
1. Remove the drain hose.
2. Remove the drain cap.
3. Insert the drain cap.
4. Connect the drain hose.
g
n
i
p
i
P
e
d
i
S
t
h
g
i
R
g
n
i
p
i
P
e
d
i
S
tf
e
L
Preparation of indoor unit
Pipe
Drain hose
①
Mounting of connecting wires
ⓐ
Open the air inlet panel.
ⓑ
Remove the lid.
ⓒ
Remove the wiring clamp.
ⓓ
Connect the connecting wire securely to the terminal block.
Use cable for interconnection wiring to avoid loosening of the
wires.
CENELEC code for cables Required field cables.
H05RNR4G1.5 (Example) or 245IEC57
H
Harmonized cable type
05 300/500 volts
R
Natural-and/or synth. rubber wire insulation
N
Polychloroprene rubber conductors insulation
R
Standed core
4or5 Number of conductors
G
One conductor of the cables is the earth conductor (yel-
low/green)
1.5 Section of copper wire (mm
2
)
Connect the connection wire securely to the terminal block. If
the wire is not affixed completely, contact will be poor, and it
is dangerous as the terminal block may heat up and catch fire.
Take care not to confuse the terminal numbers for indoor
and outdoor connections.
Earth lead wire shall be longer than the other lead wires for
the electrical safety in case of the slipping out of the cord
from the anchorage.
The earth line of power cord must be properly earthed.
Affix the connection wire using the wiring clamp.
ⓔ
Fix the connecting wire by wiring clamp.
ⓕ
Attach the lid.
ⓖ
Close the air inlet panel.
②
Shaping the pipe
③
Taping of the exterior
Hold the bottom of the pipe and change its
direction before stretching it and shaping it.
Tape only the portion that runs through the wall.
Always tape the crossover wires with the pipe.
④
Cautions when piping from the left and the rear center of the unit
[ Top View ]
Remove the screw and
drain hose, making it
rotate.
Remove it with hand
or pliers.
Insert the drain cap which was removed
at procedure “2” securely using a hex-
agonal wrench etc.
Note: Be careful that If it is not inserted
securely, water leakage may occur.
Insert the drain hose se-
curely, making rotate. And
install the screw.
Note: Be careful that If it is
not inserted securely, water
leakage may occur.
Right rear piping
Left rear piping
Left side piping
Right side piping
[Drain hose changing procedures]
Left downward
Right
Rear
Downward Left rear
Left
Piping is possible in the rear, left,
left rear, left downward, right or
downward direction.
Do not place the power supply cords above the gutter,
because the air conditioner is structured in a way where
condensation on the back side is collected in to the drain
pan before drainage.
Do not make traps in the drain hose line.
Wall
Gutter
Pipes storage area
Declining slope
Inverted slipe
Trap
Terminal block
1
3
2 N
Lid
Wiring Clamp
Summary of Contents for SRK10CNS
Page 46: ... 45 14 SRK T 153 3 Wireless remote control Unit mm 60 17 3 150 Unit mm 60 17 3 150 ...
Page 71: ... 70 14 SRK T 153 4 Troubleshooting procedure If the air conditioner runs NO YES 71 ...
Page 79: ... 78 14 SRK T 153 ...
Page 83: ... 82 14 SRK T 153 4 6 10641 ...
Page 87: ... 86 14 SRK T 153 4 6 10641 ...
Page 91: ... 90 14 SRK T 153 4 6 10641 ...
Page 95: ... 94 14 SRK T 153 4 6 10641 ...
Page 99: ... 98 14 SRK T 153 4 6 10641 ...
Page 103: ... 102 14 SRK T 153 4 6 10641 ...
Page 108: ... 107 14 SRK T 153 MEMO ...
Page 114: ... 113 14 SRK T 153 MEMO ...
Page 117: ... 116 14 SRK T 153 CRBE0290 6 11 9 10 13 14 3 15 12 2 4 8 7 5 1 7 7 PANEL FAN ASSY ...
Page 121: ... 120 14 SRK T 153 CRBE0290 6 11 9 10 13 14 3 15 12 2 4 8 7 5 1 7 7 PANEL FAN ASSY ...
Page 125: ... 124 14 SRK T 153 CRBE0290 6 11 9 10 13 14 3 15 12 2 4 8 7 5 1 7 7 PANEL FAN ASSY ...
Page 129: ... 128 14 SRK T 153 CRBE0290 6 11 9 10 13 14 3 15 12 2 4 8 7 5 1 7 7 PANEL FAN ASSY ...
Page 133: ... 132 14 SRK T 153 CRBE0290 6 11 9 10 13 14 3 15 12 2 4 8 7 5 1 7 7 PANEL FAN ASSY ...
Page 137: ... 136 14 SRK T 153 CRBE0290 6 11 9 10 13 14 3 15 12 2 4 8 7 5 1 7 7 PANEL FAN ASSY ...
Page 141: ... 140 14 SRK T 153 CRBE0221 12 16 17 1 2 3 5 6 7 8 9 10 13 16 14 15 4 11 PANEL FAN ASSY ...